23
Assembly
Type 2035 / 3236
7.7.2. Kv value
Orifice
DN
Body
connection
[mm]
Valve size
Actuator
Kv value water [m³/h] for
diaphragm material
Designation EPDM,
FKM
PFA
10
3/8"
RV50
0.8
0.7
15
1/2"
RV50
2.5
2
20
3/4"
RV50
3.5
3.3
25
1"
RV70
10
9
40
1 1/2"
RV110
27
22
50
2"
RV110
35
27
Tab. 3: Kv value
All Kv values measured on valves with connections according
to ASME BPE.
8.
asseMBly
8.1.
safety instructions
Danger!
risk of injury from high pressure in the equipment/device.
▶
Before working on equipment or device, switch off the pressure
and deaerate/drain lines.
Warning!
risk of injury from improper assembly.
▶
Installation must only be carried out by authorized technicians and
with the appropriate tools.
risk of injury from unintentional activation of the system and
uncontrolled restart.
▶
Secure system from unintentional activation.
▶
Following assembly, ensure a controlled restart.
8.2.
Before installation
• Before connecting the valve, ensure the pipelines are flush.
• Pay attention to the flow direction.
english
Summary of Contents for 2035
Page 42: ...42 Type 2035 3236 english ...
Page 82: ...82 Typ 2035 3236 deutsch ...
Page 122: ...122 Type 2035 3236 français ...
Page 123: ......
Page 124: ...www burkert com ...