6 cOnFiguraTiOn and FuncTiOn
6.1 Operating and display elements
6.1.1 Operating unit
The operating unit consists of an LCD and keys. It is used for displays and
settings of the Control Electronics, Type 8605.
4
2
1
5
7
6
Legend
1 Process value = Actual
value (of the coil current)
2 Setpoint = Setpoint (of
Setpoint (of
the coil current)
3
= active
= not active
4 Upper limit
5 Unit of the displayed
value
(s, Hz, %, mA, V)
6 Lower limit
7 LCD
Illustration 6-1: Operating unit
key assignment
Key
Display mode
Configuration
mode
Selected and
confirmed menu
item
Switch over the display
value
PV [mA] process value
PV [%] process value
SP [%] Setpoint
TV [%] duty cycle
Scroll up
(selection)
Increment (in-
crease)
numerical values
Scroll down
(selection))
Decrement (de-
crease)
numerical values
sec
Enter configuration
mode
Confirm the
selected menu
item
Select and dese-
lect the individual
menu items
Switch between
main menu and
sub-menu items
e. g.: Out-VALV
Confirm set
values