Plus-X 600 Installation and Operation Manual Rev B
4
Installation
Status Input Wiring
The Plus-
X 600 status inputs are organized into two 2x6 “Phoenix”
-type headers (four mating 6-
pin plugs are included). Pins for each channel and ground are labeled.
1
⏚
2
3
⏚
4
5
⏚
6
7
⏚
8
9
⏚
10
11
⏚
12
13
⏚
14
15
⏚
16
Metering Input Wiring
Metering inputs are available on a 2x6 “Phoenix”
-type header (two mating 6-pin plugs are
included). Pins for each channel and ground are labeled.
1
⏚
2
3
⏚
4
5
⏚
6
7
⏚
8
Command Relays
Relay Pairing
The Plus-X 600 includes 12 relays.
Relays may be used individually, or in
raise/lower pairs (for up to 6 pairs). Use
the onboard web interface to configure
relay pairing. Log on to the web interface,
select
Settings
from the menu, then
Relay Pairs
from the list on the left hand
side. Follow the onscreen instructions to
continue.
Paired Relay Example
Plus-X 600 relay #1 is paired with relay #7
and the ARC Plus has mapped the Plus-X
600’s channels starting at ARC Plus
channel #1.
In this scenario, ARC Plus Channel 1
Raise will use Plus-X 600 relay #1, and
ARC Plus Channel 1 Lower will use Plus-
X 600 relay #7. Note that ARC Plus
Channel 7 Raise and Lower are not used.
Relay Pairing