22
6. Set the adjustable angle mounting brackets to desired angle and fasten brackets by spanner
For ceiling mounted installation, the available mount angles are restricted to 0°, 15° and 30° only.
For wall mounted installation, the available mount angles are restricted to 15°, 30° and 45° only.
7. Hang the heater on the brackets and firmly secure in place with the mounting bracket locking plates by tightening
bolts labelled A.
NOTE:
Depending on material and design of ceiling structural elements, the heater must be secured with the correct
fasteners. The weight of the heater is up to 5.3Kg, the installation location must be able to hold 5 times the weight
of the heater. In the cavity above the radiator, a sufficient exchange of air for heat dissipation must be ensured.
Model No
“B”
MINIMUM DISTANCE (mm)
1200W
300 ±20
1500W
500 ±50
1800W
500 ±50
2200W
500 ±50
3000W
650±50
A
°