the national requirements in force and shall be periodically examined and replaced as
necessary.
The installation must be tested for gas tightness. Details of this procedure can be found in
IGE/UP/1.
1.4 ELECTRICAL SUPPLY
This appliance is suitable for
AC supplies only
.
The standard unit terminal arrangement is for use on a two phase supply (with neutral),
terminal block 1. By adding the links, positioned between L1, L2 and L3 on terminal
block 2, the range can be converted for single phase. Refer to wiring diagram for further
information.
The electrical ratings are 230V, 4.8kW 400V 2N˜ (4.8kW) L1 = 2.4 kW/ L2 = 2.4kW
1.5 GAS PRESSURE ADJUSTMENT - NATURAL AND PROPANE GAS
Country Appliance Category
Gas
Inlet Pressure
GB/IE
A
1
, I
2H
Natural gas (G20)
20mbar
GB/IE
A
1
, I
3P
Propane (G31)
37mbar
1.6 HEAT INPUTS - ELECTRICAL / NATURAL AND PROPANE GAS
Gas Heat Input
(kW net)
Gas Heat Input,
Low Setting
(kW net)
Electrical Input,
(kW)
Country Gas
Hotplate
Total
Hotplate
Oven
GB/IE
Natural gas (G20) 6.10kW x6 36.6kW
0.95kW
4.8kW
GB/IE
Propane (G31)
5.40kW x6 32.4kW
0.95kW
4.8kW
1.7 INJECTOR & BYPASS STAMPINGS - NATURAL AND PROPANE GAS
Injector Stamping
Bypass Screw Stamping
Country Gas
Hotplate - see spares
page for identification
of hotplate types
Hotplate
GB/IE
Natural gas (G20) 193 (type 1)
200 (type 2)
48 adj. out
GB/IE
Propane (G31)
120 (type 1 & 2)
48 screwed in
Pressure test point is located towards the centre of gas manifold situated behind front
control facia.