Eco Mode (Filter models only): 

When no water is drawn from the boiler in 2 hours, the eco mode is engaged. The backlight turns

 

off and 

the only data displayed is the Burco logo along with the time and the status indicator. Water should be 

drawn off to resume normal operation. To set the Eco mode timer, simply scroll down to ‘ON’ to set the 

desired time. Once you are happy with the time that has been set, press the menu button to confirm this. 

This will then take you to ‘OFF’, where you can then set the time that you want the Eco mode to finish. If 

you want to turn the Eco mode off altogether, simply scroll down and select ‘OFF’.

 

 

TO EXIT MENUS, PRESS THE STANDBY BUTTON 

 

Heating up:  

HEATING  will  flash  on  controller  screen  during  the  heating  up 

period. LOW TEMP may be shown on the screen during this time. 

When selected temperature is achieved 

 READY is shown.

 

Filling: 

Once  the  INITIAL  SET  UP  is  complete,  the  filling  process  will 

start.  The  LCD  Screen  will  show  the  word  FILLING.  After  the 

filling is complete, the heating will start until it reaches the set 

temperature. The LCD Screen will show the word HEATING.

 

Filter Life (Filtration models only): 

During operation,  the  bars fill to  represent filter usage. Once 

exhausted, all the bars are solid and the fault code for changing 

the filter is displayed. The unit should be powered down. Filters 

replaced and filter counter reset (refer to replacement parts).

 

ECO MODE

 

SET CLOCK 

SCREEN SETTINGS 

LANGUAGE 

Summary of Contents for 069764

Page 1: ...069832 Burco Slimline Autofill s 070012 070043 070029 070050 N A Glen Dimplex All rights reserved Material contained in this publication may not be reproduced in whole or in part without prior permis...

Page 2: ...kW models 9 7 5 6kW Twin Tap Model 10 7 6 Overflow and Drainage 10 8 0 Operating Instructions 11 8 1 Boiler Overview 11 8 2 Controller Overview 12 8 3 Controller Set Up 13 9 0 Descaling Cleaning advic...

Page 3: ...eed to contact us for any reason Model Number 0 Serial Number this can be found on the data badge on the back of the product Date of purchase Purchased from In your instruction pack you will find a du...

Page 4: ...ecautions WARNING THIS SYMBOL MEANS THERE IS A RISK OF PERSONAL INJURY IMPORTANT THIS SYMBOL MEANS THERE IS A RISK OF DAMAGING THE APPLIANCE THIS APPLIANCE MUST BE INSTALLED COMMISSIONED AND SERVICED...

Page 5: ...R MAINTENANCE SHALL NOT BE MADE BY CHILDREN WITHOUT SUPERVISION DISCONNECT APPLIANCE BEFORE SERVICING MAINTENANCE OR CLEANING IF THE SUPPLY CORD IS DAMAGED IT MUST BE REPLACED BY THE MANUFACTURER ITS...

Page 6: ...rranty Information Non Filtered Burco boilers come with a comprehensive 1 year parts and labour warranty 069825 069832 If you have purchased a Burco boiler with a water filter then the warranty is 2 y...

Page 7: ...SL5L PB SL10L PB Height mm 457 695 518 627 Width mm 358 215 Depth mm 464 373 Capacity Litres 5 20 5 10 Weight Kg 13 16 18 13 14 Ambient Temperature C 5 C 30 C Water Inlet Pressure Bar 1 8 Bar Voltage...

Page 8: ...not have a water filter system included we recommend you fit a separate water filter between the boiler and the mains supply Always ensure mains water supply is turned off or localised isolation valve...

Page 9: ...re Code Green Yellow Wires Earth E Blue Wire Neutral N Brown Wire Live L The supply cord on the 3kW appliance is of a special type If replaced only a Burco supply cord must be used Note the supply cor...

Page 10: ...that an overflow would occur The boiler is primarily designed so that any overflow occurrence and condensation is directly vented to the spillage tray As an option the boiler overflow outlet may be c...

Page 11: ...te the black lug 2 Carefully drill the plastic barrier inside the lug 3 Connect to the waste drainage with a flexible pipe 8 0 Operating Instructions Burco boilers are designed for continuous operatio...

Page 12: ...Ensure boiler is connected to the mains water supply Turn on the mains power and press and hold the power button for 10 seconds The boiler should begin filling and heating Ensure boiler is set to 98...

Page 13: ...When the Screen Lock function is active settings cannot be changed Press and hold the same buttons to deactivate the screen lock function If in locked mode the lock logo will blink on the screen for a...

Page 14: ...flash Use the SCROLL buttons to choose between 5 levels of backlight brightness Hold MENU to store Now the contrast values will flash Repeat for the contrast Hold MENU to store and to exit Language Pr...

Page 15: ...n and select OFF TO EXIT MENUS PRESS THE STANDBY BUTTON Heating up HEATING will flash on controller screen during the heating up period LOW TEMP may be shown on the screen during this time When select...

Page 16: ...and release to stop see image 1 If you turn the plastic tap handle through 180 degrees the tap will be in Constant mode see image 2 Now when you pull the tap towards you it will remain locked downwar...

Page 17: ...e electricity and allow the boiler to operate normally for approximately 45 minutes 7 Isolate turn off the boiler and allow to cool down 8 Remove the tank cap again to inspect the tank and level detec...

Page 18: ...ent supplier or alternatively order replacements via 44 0 344 879 3588 www burco co uk It is important that you descale your water boiler regularly particularly in hard water areas Failure to descale...

Page 19: ...ime scale build up Stubborn stains may be removed using a good stainless steel cleaner or non abrasive cleaner Hard to reach areas should be cleaned using a soft brush mild cleaning solution Failure t...

Page 20: ...will take you to the Burco website If you believe your Burco Boiler isn t working correctly please contact our Aftersales Team on 44 0 344 879 3588 13 0 Disposal At the end of the appliance s useful...

Page 21: ...ation or to purchase spare parts please contact our Aftersales team on 44 0 344 879 3588 Please ensure you have the details of the model and serial numbers to hand These can be found in the About my p...

Page 22: ...urchase spare parts please contact our Aftersales team on 44 0 344 879 3588 Please ensure you have the details of the model and serial numbers to hand These can be found in the About my product sectio...

Page 23: ...to mains power water and that there is no blockage kink in the supply hose Q My screen is not illuminating A Check the appliance is connected to mains power and turned on then adjust the brightness co...

Page 24: ...bility of the site If the boiler has not been descaled when our Service Engineer visits the service call will be chargeable Q Can I purchase any replacementparts A Yes we have several replacement part...

Page 25: ...ed details of your Burco product its serial number and a description of the fault which has occurred You can find the model number and serial number for your Burco product on the heaters side Once we...

Page 26: ...ailure to assemble install clean and maintain your Burco product in accordance with the Operating Instructions supplied with the product unless this was carried out by Burco or its authorised dealers...

Page 27: ...that are replaced will become the property of Burco Any repairs performed under the Burco Warranty will not extend the Warranty Period Any replacement of your Burco product by Burco during the Warran...

Page 28: ...of this product Glen Dimplex reserve the right to revise products literature and guarantee terms without prior notice due to a policy of continuous improvement To speak to customer services please co...

Reviews: