TROUBLE SHOOTING GUIDE CHECKLIST
NEVER MAKE ADJUSTMENTS TO ANY ELECTRICAL APPLIANCE OR PRODUCT WITH THE POWER
CONNECTED. DON’T JUST UNSCREW THE FUSE OR TRIP THE BREAKER, REMOVE THE POWER
FROM THE RECEPTACLE.
TROUBLE
PROBABLE CAUSE
ACTION
Blown fuse
Tripped breaker
Inadequate power supply
Faulty pressure switch
Faulty submersible cable
Faulty control box
Loose wire connections
Sand-locked pump
Water logged tank
Pressure switch setting incorrect
Check valve in pump-end stuck Open
Leak in piping system
Faulty pressure switch
Check valve stuck closed
Low water level in well
Blocked suction intake screen
Control box location not ventilated-too-
HOT
Faulty cable or motor
Faulty control box
Incorrect voltage
Replace
Reset
Check voltage
Check / replace
Check for breaks in cable
Have an electrician, check control box
Check and repair
Pull pump and check for sand, mud or silt
Repeat step 10
Repeat step 9
Check and replace
Check and repair piping
Check and replace
Pull pump and check valve, replace valve
Check water level
Install pump lower
Remove pump and check
Check location and change
Have electrician, check for resistance
Replace
Call an electrician
Motor does not
run.
Motor starts
too often.
Motor runs
continuously.
Motor runs
BUT overload
protector
TRIPS.
Under no circumstances should the elctrician rating of the overload protector
be increased or the protector BY-PASSED in an attempt to break free a seized
pump. Motor failure invariably results and the warranty is void.
ELECTRICAL TEST : Consult an electrician for all electrical testing.
VOLTAGE TEST : Voltage should be within 10% of the motor nameplate. If more
or less, consult your Hydro company.
AMPERAGE TEST : Locked motor-rotor AMPS is 4-5 times normal Amps. IDL
AMPS-Less than normal Amps. Pump may be sand locked-pull and clean.
RESISTANCE TEST : if ohmmeter reading is high, the circuit is open. Low
reading indicates there is a ‘‘short circuit’’. Situation must be corrected and
further check of all wiring is in order.
WARNING : Serious or fatal shock may result from the failure to ground all
metal plumbing and the motor to the power supply ground when pump is on
the outside of a drilled well. Do not install pump in lake around swimmig areas.