CALIBRATE FLOW
This function allows the operator to test and enter the
actual flow rate of the sprayhead(s) and the bypass/
dilution for each side of the brewer by dispensing each
separately for one minute. The volumes are then entered
into the brewer.
Procedure to calibrate the sprayhead flow rate:
1. Place a container, accurately graduated with a
minimum capacity of 60 ounces, under the funnel.
2. Press and hold the right hidden button until the
display reads
RECIPES.
Press the right hidden
button until the display reads
CALIBRATION
, then
press
SELECT
. Press and release the right hidden
switch until the display reads
CALIBRATE
, then
press
SELECT
.
3. Select to advance to
SPRAY HEAD CAL
screen.
4. Select side to calibrate.
The display should read
CONTAINER READY?
If
container is under the funnel, select
YES
.
5. The display should read
CALIBRATE SPRAY.
Press
and release any
BREW
button on the side to be cali-
brated to begin the sprayhead flow for calibration.
The display should read
CALIBRATE SPRAY...60
SEC TO FINISH.
The 60-second timer on the display
will count down to zero. When the counter reaches
zero, the display will change to
LEFT or RIGHT OZ
,
along with a number.
6. Measure the amount of water in the container and
use
(-)
and
(+)
to match the display to the amount
in the container. Then select
DONE
.
7. The display should now read
NEW L or NEW R
SPRY FLOW
, along with the correct flow rate of
the sprayhead. After about 5 seconds, the display
will return to the
CALIBRATE FLOW
screen.
8. Repeat steps 1-7 to calibrate the other side.
9. To exit the
CALIBRATE FLOW
function and advance
to the next screen, select
NO.
To exit programming
and return to the
MAIN SCREEN
, press either
ENABLE BREW ON/OFF
switch.
PROGRAMMING FUNCTIONS (cont.)
Procedure to calibrate the bypass flow rate:
1. Place a container, accurately graduated with a
minimum capacity of 60 ounces, under the funnel.
2. Press and hold the right hidden button until the
display reads
RECIPES.
Press the right hidden
button until the display reads
CALIBRATION
, then
press
SELECT
. Press and release the right hidden
switch until the display reads
CALIBRATE
, then
press
SELECT
.
3. Select to advance to
BYPASS CAL
screen.
4. Select side to calibrate.
The display should read
CONTAINER READY?
If
container is under the funnel, select
YES
.
5. The display should read
CALIBRATE BYPASS.
Press
any
BREW
button on the side to be calibrated to
begin the flow for calibration. The display should
read
CALIBRATE BYPASS...60 SEC TO FINISH.
The
60-second timer on the display will count down to
zero. When the counter reaches zero, the display
will change to
LEFT
or
RIGHT OZ/M
, along with a
number.
6. Measure the amount of water in the container and
using the
(-)
and
(+)
, adjust the amount on the
display to match the amount in the container. Then
select
DONE
.
7. The display should now read
NEW L
or
NEW R
BYPS FLOW
, along with the correct flow rate of
the bypass. After about 5 seconds, the display will
return to the
CALIBRATE FLOW
screen.
8. Repeat steps 1-7 to calibrate the other side.
9. To exit the
CALIBRATE FLOW
function and advance
to the next function screen, select NO. To exit
programming and return to the
MAIN SCREEN
,
press
ENABLE BREW ON/OFF
switch.