Model
Product #
Volts
Amps Tank Heater Total
Brewing
Cubic
Shipping
Cord
Watts
Watts Capacity
Measure Weight Attached
cWt15–3
††
12950.0112
120
13.9
1320
1670 3.9 gal./hr.
6.4 ft
3
32 lbs.
Yes
cWtF15–3 12950.0212
120
13.9
1320
1670 3.9 gal./hr.
6.4 ft
3
35 lbs.
Yes
cWtF15–3* 12950.0216
120
13.9
1320
1670 3.9 gal./hr.
6.4 ft
3
36 lbs.
Yes
cWtF20–3 12950.0232
120
17.9
1800
2150 5.3 gal./hr.
6.4 ft
3
35 lbs.
No
cWtF35–3 12950.0252 120/208-240 17.1
†
3500
3850 7.5 gal./hr.
6.4 ft
3
35 lbs.
No
cWtF15
12950.0298
120
13.9
1320
1670 3.9 gal./hr.
6.4 ft
3
35 lbs.
Yes
(3 left lower warmers)
cWtF35*
12950.0381 120/208-240 17.1
†
3500
3850 7.5 gal./hr.
6.4 ft
3
39 lbs.
No
*Stainless steel funnel
†
Current at 240 Volts
††
No faucet
Brewing capacity:
based upon incoming water temp of 60ºF/15˚C (140ºF/60˚C rise) per 1/2 gallon brew time of 4 minutes.
Models listed as 120/208V or 120/240V must be connected to 208V or 240V electrical service respectively. Please refer to the installation manual.
electrical: model 15 requires 2-wires plus ground service rated 120V, single phase, 60 Hz.
model 20 requires 2-wires plus ground service rated 120V, single phase, 60 Hz.
model 35 requires 3-wires plus ground service rated 120/208 or 120/240V, single phase, 60 Hz.
Plumbing: 20-90 psi (138-621 kPa). machine supplied with