Bunn Axiom Series Technical Training Manual Download Page 9

Bunn-O-Matic Corporation

9

Freq&AdjustCaps Menu

* An asterisk will appear if a RFID carafe is placed on a warmer 

element.

The 4-digit number located in the middle of the main, top front 

and top rear warmers can be used as a reference during trouble-

shooting.

•  4-digit number steady:

 

Means the coil frequency is staying 

      tuned 

to the nominal value of 125.0 khz.

•  4-digit number flashing: Means the coil frequency is at the 

      low end of tuning, which will result in intermittent or failure of 

      writing and reading of the RFID carafes.

Faucet Assembly

The tube that’s connected from the tank to the faucet is now stainless with an 

insulation wrap around it to help insulate the tube from temperature loss. The 

requirement for the oatmeal mixing is 185°F water and a flow dispense of 5 

ounces within 15 seconds.

RFID Glass Carafe 

The glass carafe has an attached collar and strap that contains the RFID 

transponder. The transponder is located within the strap holder, which contains 

the assigned date and time recorded from the initial start of a brew cycle. The 

operational range for reading and writing from the RFID sensor is approximately 

.3/4 inches.

The collar and strap with transponder can be replaced as a complete kit (Bunn 

PN: 42930.1000) on the glass carafe. See instruction sheet 43520.0000.

RFID Thermal Carafe 

The thermal carafe has an attached RFID transponder holder adhered to the 

side wall of the stainless housing. The brewer RFID board automatically can 

sense when a thermal carafe is set on the warmer and will use the “Thermal 

Fresh Hours” menu which is set at a 2 hours. The display will read “Ready To 

Brew Thermal Carafe”. Anytime a thermal carafe is sensed, the corresponding 

warmer will not activate or turn on. The operation range is the same distance as 

the glass carafe but the transponder is not replaceable on the thermal carafe. A 

new carafe will need to be ordered if the transponder fails or housing releases 

from the stainless carafe housing.

4-Digit Numbers

Asterisk Indicates

Carafe is on Main

Warmer

Summary of Contents for Axiom Series

Page 1: ...AXIOM RFID Technology Technical Training...

Page 2: ...d differences between a standard AXIOM and an AXIOM equipped with RFID The learner will be able to identify the components and functions of the RFID system Given an operating machine the learner will...

Page 3: ...ogram Menus Left Hidden Switch Programming Access Switch Right Hidden Switch Additional Digital 3 Click Brew Volume Setup Additional LED Color Change for Freshness Indicator Warning Alert Message and...

Page 4: ...ore pieces of the same equipment are going to be installed in the same location it s very important to make sure that all the date and time settings are set identical throughout the equipment for the...

Page 5: ...mming menus Thermal Fresh Hours is the same definition as the Glass Fresh Hours Note Brewer senses a Thermal carafe on any warmer plate warmer plates will not operate Sets the amount of time that the...

Page 6: ...e alarm Sets the amount of delay between the expired alarm beeps Default 10 Range 5 300 sec Select Yes to adjust the beeper volume Sets the volume of the beeper for expiration and pre expire alarm Def...

Page 7: ...nal 3 click brew volume setup If the program lockout switch is in the lock position on the control board while performing the 3 click volume setup procedure the new calibration time or volume will not...

Page 8: ...ration alarm will sound an audible beep when the coffee freshness time has expired or when the flashing red LED is visible The alarm will beep once every ten seconds The pre expiration alarm will soun...

Page 9: ...ransponder is located within the strap holder which contains the assigned date and time recorded from the initial start of a brew cycle The operational range for reading and writing from the RFID sens...

Reviews: