Press “+” or “-” to adjust the hour.
Press “+” or “-” to adjust the minutes.
Press “+” or “-” to adjust the seconds.
Enable/disable the 5 minute warning beep sequence for a carafe that’s about to expire.
Sequence: The last 5 minutes of the freshness time remaining message or the
corresponding warmer flashing yellow LED; the pre-expire alarm will beep once a
minute with a total of 5 beeps before the every 10 second expiration alarm takes over.
Digital 3-Click Brew Volume Setup
The digital 3-click volume setup is added for the convenience of setting pot levels. The segment of adding or sub-
tracting an ounce of water during setup is not possible. This method of calibrating pot levels is more user friendly to
the operator than entering the programming menus using the right hidden switch and then making the volume adjust-
ment.
Note: The brew oz. volume will automatically change on this screen when you perform
the optional 3-click brew volume setup. If the program lockout switch is in the lock
position on the control board, while performing the 3-click volume setup procedure, the
new calibration time or volume will not hold and will go back to the original setting. You
have the perception of calibrating a new volume without any warning of the lockout
switch being locked.
Freshness Indicator LED Color Sequence
The freshness time remaining message will operate in conjunction with the warmer element LED color sequence.
Green LED
The green color means you are within the freshness time limit (0.5 hrs/glass).
Flashing Yellow LED
The yellow color is a warning indicator, which tells the operator that the glass freshness time is about to expire. The
LED will change from green to yellow when the freshness time reaches the last five minutes of the freshness time
limit (0.5 hrs/glass).
Flashing Red LED
The red color means that the freshness time has expired and the warmer element is about to turn off automatically.
Note: When the “Freshness Expired” message or the flashing red LED appears, the warmer will turn off automatically
after five minutes.