Bunn Axiom Series Technical Training Manual Download Page 7

Bunn-O-Matic Corporation

7

 

Press “+” or “-” to adjust the hour.

Press “+” or “-” to adjust the minutes.

 

  Press “+” or “-” to adjust the seconds.

  Enable/disable the 5 minute warning beep sequence for a carafe that’s about to expire.

  Sequence: The last 5 minutes of the freshness time remaining message or the 

  corresponding warmer flashing yellow LED; the pre-expire alarm will beep once a  

  minute with a total of 5 beeps before the every 10 second expiration alarm takes over.

Digital 3-Click Brew Volume Setup

The digital 3-click volume setup is added for the convenience of setting pot levels. The segment of adding or sub-

tracting an ounce of water during setup is not possible. This method of calibrating pot levels is more user friendly to 

the operator than entering the programming menus using the right hidden switch and then making the volume adjust-

ment.

 

  Note: The brew oz. volume will automatically change on this screen when you perform  

  the optional 3-click brew volume setup. If the program lockout switch is in the lock 

  position on the control board, while performing the 3-click volume setup procedure, the  

  new calibration time or volume will not hold and will go back to the original setting. You  

  have the perception of calibrating a new volume without any warning of the lockout  

 

 

 

 

switch being locked.

Freshness Indicator LED Color Sequence

The freshness time remaining message will operate in conjunction with the warmer element LED color sequence.

Green LED

The green color means you are within the freshness time limit (0.5 hrs/glass).

Flashing Yellow LED

The yellow color is a warning indicator, which tells the operator that the glass freshness time is about to expire. The 

LED will change from green to yellow when the freshness time reaches the last five minutes of the freshness time 

limit (0.5 hrs/glass).

Flashing Red LED

The red color means that the freshness time has expired and the warmer element is about to turn off automatically.

Note: When the “Freshness Expired” message or the flashing red LED appears, the warmer will turn off automatically 

after five minutes.

Summary of Contents for Axiom Series

Page 1: ...AXIOM RFID Technology Technical Training...

Page 2: ...d differences between a standard AXIOM and an AXIOM equipped with RFID The learner will be able to identify the components and functions of the RFID system Given an operating machine the learner will...

Page 3: ...ogram Menus Left Hidden Switch Programming Access Switch Right Hidden Switch Additional Digital 3 Click Brew Volume Setup Additional LED Color Change for Freshness Indicator Warning Alert Message and...

Page 4: ...ore pieces of the same equipment are going to be installed in the same location it s very important to make sure that all the date and time settings are set identical throughout the equipment for the...

Page 5: ...mming menus Thermal Fresh Hours is the same definition as the Glass Fresh Hours Note Brewer senses a Thermal carafe on any warmer plate warmer plates will not operate Sets the amount of time that the...

Page 6: ...e alarm Sets the amount of delay between the expired alarm beeps Default 10 Range 5 300 sec Select Yes to adjust the beeper volume Sets the volume of the beeper for expiration and pre expire alarm Def...

Page 7: ...nal 3 click brew volume setup If the program lockout switch is in the lock position on the control board while performing the 3 click volume setup procedure the new calibration time or volume will not...

Page 8: ...ration alarm will sound an audible beep when the coffee freshness time has expired or when the flashing red LED is visible The alarm will beep once every ten seconds The pre expiration alarm will soun...

Page 9: ...ransponder is located within the strap holder which contains the assigned date and time recorded from the initial start of a brew cycle The operational range for reading and writing from the RFID sens...