Bunn AXIOM BREWWISE Series Installation & Operating Manual Download Page 3

Page 3

PN: 00658.0000G  02/08  © 1985 BUNN-O-MATIC CORPORATION

#00658.0000

#37881.0000

39130.4 040212

#00986.0000

USER NOTICES

Carefully read and follow all notices in this manual and on the equipment.  All labels on the equipment should 

be kept in good condition.  Replace any unreadable or damaged labels.

To reduce the risk of electric shock,

do not remove or open cover.

No user-serviceable parts inside.

Authorized service personnel only.

Disconnect power before servicing.

#03408.0002

#03409.0002

#12364.0000

WA R M E R S   A N D   S U R FAC E S   A R E   H OT  

CAUTION 

#02765.0000

#00656.0001

As directed in the International Plumbing Code of the 

International Code Council and the Food Code 

Manual of the Food and Drug Administration (FDA), 

this equipment must be installed with adequate 

backflow prevention to comply with federal, state 

and local codes. For models installed outside the 

U.S.A., you must comply with the applicable Plumb-

ing /Sanitation Code for your area.

Optional Field Wiring

 

 
 

120/208-240 V,  15.6-17.5 A,  2980-3850 W 

1PH,  3-Wire + GND,  60HZ 

#29710.0007

#37881.0002

INTRODUCTION

This equipment will brew a 

1

gallon batch of coffee into an awaiting server. The brewer may have 

a hot water faucet for allied beverage use. It is only for indoor use on a sturdy counter or shelf.

CONTENTS

Warranty ................................................................................................ 2
User Notices ......................................................................................... 3
Electrical Requirements ........................................................................ 4
Plumbing Requirements & Initial Set-Up ............................................... 6
Operating Controls & Coffee Brewing ................................................... 7
Cleaning & Tank Drain .......................................................................... 8
Adjustments & Optional Settings .......................................................... 9

To reduce the risk of electric shock, 

do not remove or open cover.

No user-serviceable parts inside.

Authorized service personnel only.

Disconnect power before servicing.

#00824.0002

#00824.0001

WARNING

• DO NOT OVERLOAD CIRCUIT.

• ALWAYS ELECTRICALLY GROUND

  THE CHASSIS.

• DO NOT DEFORM PLUG OR CORD.

• FOLLOW NATIONAL AND LOCAL

  ELECTRICAL CODES.

• KEEP COMBUSTIBLES AWAY.

FAILURE TO COMPLY RISKS EQUIPMENT

DAMAGE, FIRE OR SHOCK HAZARD.

READ THE ENTIRE

OPERATING MANUAL BEFORE

USING THIS PRODUCT

00986.0000F  10/07   ©1994  Bunn-O-Matic Corporation

Summary of Contents for AXIOM BREWWISE Series

Page 1: ...ision of the Operating Manual or to view the Illustrated Parts Catalog Programming Manual or Service Manual please visit the Bunn O Matic website at www bunn com This is absolutely FREE and the quicke...

Page 2: ...es that are binding on BUNN Accordingly statements by such individuals whether oral or written do not constitute warranties and should not be relied upon If BUNN determines in its sole discretion that...

Page 3: ...applicable Plumb ing Sanitation Code for your area Optional Field Wiring 120 208 240 V 15 6 17 5 A 2980 3850 W 1PH 3 Wire GND 60HZ 29710 0007 37881 0002 INTRODUCTION This equipment will brew a 1 2 ga...

Page 4: ...k 10 Set voltage switch to the appropriate position and replace the access panel DV Models Only 11 If plumbing is to be hooked up later be sure the brewer is disconnected from the power source If plum...

Page 5: ...res Suitable For At Least 90 C 194 F FOR USE ONLY ON AN INDIVIDUAL BRANCH CIRCUIT RATED 20 AMPS Dual Voltage Switch in 120V position Dual Voltage Switch in 120 208 240V position 120 208 120 240V AC Si...

Page 6: ...unter top Bunn O Matic does not recommend the use of a saddle valve to install the brewer The size and shape of the hole made in the supply line by this type of device may restrict water flow 1 Insert...

Page 7: ...tip carefully remove the brew funnel and discard the grounds and filter 39130 4 040212 D A ENABLE BREW ON OFF SWITCH Pressingthe ENABLEBREWON OFF switch indicatoron supplies power to the brew station...

Page 8: ...problems in the brewer and takes less than a minute NOTE In the event that the Brew Logic circuit activates compensating for high lime build up it will temporarily disable the Recovery Booster and Pu...

Page 9: ...to their specifications PROGRAMMING SWITCHES 1 FUNCTION SCREEN This is the display which shows the various functions 2 Right of the display This is used to access the program mode and is also used to...

Page 10: ...DONE ENTER PASSWORD 0 0 0 BREW LOCKOUT NO DONE YES PROGRAMMING FUNCTIONS OVERVIEW BrewWIZARD EXITING BrewWIZARD UNITS METRIC DONE ENG SET LANGUAGE NO YES SET PASSWORD 0 0 0 ENTER SERVICE NO YES BREW O...

Page 11: ...xx xx FACTORY DEFAULTS NO YES SERVICE TOOLS NO YES BREW COUNTERS NO YES ENABLE BrewLOGIC NO DONE YES 0 REFILL 155 DONE ENABLE CLEAN NO DONE YES SET PULSE BREW NO YES ADJUSTMENTS OPTIONAL SETTINGS CON...

Page 12: ...o the MAIN SCREEN Always remember to place an empty server and funnel under the sprayhead when operating the brewer during the set up of PULSE BREW CALIBRATE FLOW and testing the brew valve in SER VIC...

Page 13: ...TTINGS CONT This function allows the operator to adjust the brew strength extraction time Setting 1 will produce a non pulsed brew cycle and the highest 14 will give you the longest time utilizing pul...

Page 14: ...right hidden switch until the display reads AXIOM VERSION Press and release the right hidden switch until the display reads CALIBRATE FLOW 3 Select YES The display should read CONTAINER READY If cont...

Page 15: ...ON OFF switch 10 The display will now read A with a flashing cursor below it Press and hold the SCROLL switchtoscrollthroughthealphabetandavail able characters When the desired character is shown on t...

Page 16: ...NE YES SCROL THRU ALPHA NEXT NEXT LETTER A SCROLL DONE NEXT WRITE BTM LINE NO YES SAVE NO EDIT YES ADVERTISEMENT SETUP COMPLETE ADJUSTMENTS OPTIONAL SETTINGS CONT ENTER SERVICE ENTER SERVICE ADVERTISE...

Page 17: ...red 5 Press and release the DONE switch The displaywillnowread EXITINGBrewWIZARD and then ENTER PASSWORD ENTER PASSWORD This function allows the operator to enter a 3 digit number to access LEVEL 2 If...

Page 18: ...O YES NOTE If the brewer is set for Metric Units displays will be different ex Brew oz will become Brew milliliters F will be C Adjusts brew tank temperature RANGE 185 to 205 F or 85 to 96 C This func...

Page 19: ...or reduce the tank temp to 140 F or 60 C once the set idle time has expired Range 0 5 24 0 hrs Enabl EnergySavr NO DONE YES 39130 4 040212 0 REFILL 155 DONE Adjusts the sensitivity of the refill circu...

Page 20: ...ispense is being performed Tank heaters are turned off and the unit will dispense for 1 minute to cool tank temperature ADJUSTMENTS OPTIONAL SETTINGS CONT 39130 4 040212 FACTORY DEFAULTS NO YES SERVIC...

Reviews: