LOCK

SET

ADJUSTMENTS & OPTIONAL SETTINGS

MAIN SCREEN

BREW LOCKOUT

 

This function allows the operator to prevent 

or allow brewing if the water temperature is less 
than the set READY temperature.
 

To access this function screen press and hold 

the right hidden switch. Release when the display 
reads: "BREW WIZARD" it will then read:

Press here 

for 

NO

Press here 

for 

DONE

Press here 

for 

YES

PROGRAM FUNCTIONS - BREW WIZARD

PROGRAMMING THE BREWER

 

The programming of the brewer is divided into two levels. Brewing adjustments are in "BrewWiz-

ard". Service functions are accessed in Level 2.
 

 The following function screens are in order of appearance. Each screen will have instructions on 

how to access, and the procedures to program the various functions of the brewer.

IMPORTANT PROGRAMMING NOTES

- READ CAREFULLY - 

 

To exit the programming mode at any time, press and release "ENABLE BREW ON/OFF" switch 

located on the front switch panel. The display will return to the MAIN SCREEN.
 

If none of the five programming switches are pressed within one minute during the setup of the 

brewer, the programming of the function screen that is being set will be exited and the display will 
return to the MAIN SCREEN.
 

Always remember to place an empty server and funnel under the sprayhead when operating the 

brewer during the set-up of PULSE BREW, CALIBRATE FLOW and testing the brew valve in SER-
VICE TOOLS/TEST OUTPUTS.

BREW  LOCKOUT?

 NO 

DONE 

YES

READY TO BREW

WATER TEMP: 200°

PROGRAMMING LOCKOUT SWITCH 

(Mounted on main control board)

This switch can be set to prevent access to the 
programming settings of the brewer. Once all the 
correct brew settings are programmed, the operator 
can set the switch to the "LOCK" position to prohibit 
anyone from changing the settings. With the switch 
in the "LOCK" position, the programming menus 
can still be accessed to view the current settings. 
However, no changes will be saved.

The YES or NO should be flashing. Select YES 
to prevent brewing if the water temperature is 
below the set READY temperature. Select NO 
to permit brewing at any water temperature.
When finished, press and release DONE. This 
will step to the next function screen. To return 
to the MAIN SCREEN at any time, press and 
release "ENABLE BREW ON/OFF".

Disconnect brewer from 

power source before 

removing any panel!

39130.4 040212

MAIN SCREEN

The main screen will alternate between "READY 
TO BREW"/"WATER TEMP" and TIME/DATE/
YEAR. Will also indicate if the glass or thermal 
carafes are ready to brew into (green lights) or 
almost expired (yellow lights) or expired (red 
lights)

Summary of Contents for AXIOM BREWWISE Series

Page 1: ...ision of the Operating Manual or to view the Illustrated Parts Catalog Programming Manual or Service Manual please visit the Bunn O Matic website at www bunn com This is absolutely FREE and the quicke...

Page 2: ...es that are binding on BUNN Accordingly statements by such individuals whether oral or written do not constitute warranties and should not be relied upon If BUNN determines in its sole discretion that...

Page 3: ...applicable Plumb ing Sanitation Code for your area Optional Field Wiring 120 208 240 V 15 6 17 5 A 2980 3850 W 1PH 3 Wire GND 60HZ 29710 0007 37881 0002 INTRODUCTION This equipment will brew a 1 2 ga...

Page 4: ...k 10 Set voltage switch to the appropriate position and replace the access panel DV Models Only 11 If plumbing is to be hooked up later be sure the brewer is disconnected from the power source If plum...

Page 5: ...res Suitable For At Least 90 C 194 F FOR USE ONLY ON AN INDIVIDUAL BRANCH CIRCUIT RATED 20 AMPS Dual Voltage Switch in 120V position Dual Voltage Switch in 120 208 240V position 120 208 120 240V AC Si...

Page 6: ...unter top Bunn O Matic does not recommend the use of a saddle valve to install the brewer The size and shape of the hole made in the supply line by this type of device may restrict water flow 1 Insert...

Page 7: ...tip carefully remove the brew funnel and discard the grounds and filter 39130 4 040212 D A ENABLE BREW ON OFF SWITCH Pressingthe ENABLEBREWON OFF switch indicatoron supplies power to the brew station...

Page 8: ...problems in the brewer and takes less than a minute NOTE In the event that the Brew Logic circuit activates compensating for high lime build up it will temporarily disable the Recovery Booster and Pu...

Page 9: ...to their specifications PROGRAMMING SWITCHES 1 FUNCTION SCREEN This is the display which shows the various functions 2 Right of the display This is used to access the program mode and is also used to...

Page 10: ...DONE ENTER PASSWORD 0 0 0 BREW LOCKOUT NO DONE YES PROGRAMMING FUNCTIONS OVERVIEW BrewWIZARD EXITING BrewWIZARD UNITS METRIC DONE ENG SET LANGUAGE NO YES SET PASSWORD 0 0 0 ENTER SERVICE NO YES BREW O...

Page 11: ...xx xx FACTORY DEFAULTS NO YES SERVICE TOOLS NO YES BREW COUNTERS NO YES ENABLE BrewLOGIC NO DONE YES 0 REFILL 155 DONE ENABLE CLEAN NO DONE YES SET PULSE BREW NO YES ADJUSTMENTS OPTIONAL SETTINGS CON...

Page 12: ...o the MAIN SCREEN Always remember to place an empty server and funnel under the sprayhead when operating the brewer during the set up of PULSE BREW CALIBRATE FLOW and testing the brew valve in SER VIC...

Page 13: ...TTINGS CONT This function allows the operator to adjust the brew strength extraction time Setting 1 will produce a non pulsed brew cycle and the highest 14 will give you the longest time utilizing pul...

Page 14: ...right hidden switch until the display reads AXIOM VERSION Press and release the right hidden switch until the display reads CALIBRATE FLOW 3 Select YES The display should read CONTAINER READY If cont...

Page 15: ...ON OFF switch 10 The display will now read A with a flashing cursor below it Press and hold the SCROLL switchtoscrollthroughthealphabetandavail able characters When the desired character is shown on t...

Page 16: ...NE YES SCROL THRU ALPHA NEXT NEXT LETTER A SCROLL DONE NEXT WRITE BTM LINE NO YES SAVE NO EDIT YES ADVERTISEMENT SETUP COMPLETE ADJUSTMENTS OPTIONAL SETTINGS CONT ENTER SERVICE ENTER SERVICE ADVERTISE...

Page 17: ...red 5 Press and release the DONE switch The displaywillnowread EXITINGBrewWIZARD and then ENTER PASSWORD ENTER PASSWORD This function allows the operator to enter a 3 digit number to access LEVEL 2 If...

Page 18: ...O YES NOTE If the brewer is set for Metric Units displays will be different ex Brew oz will become Brew milliliters F will be C Adjusts brew tank temperature RANGE 185 to 205 F or 85 to 96 C This func...

Page 19: ...or reduce the tank temp to 140 F or 60 C once the set idle time has expired Range 0 5 24 0 hrs Enabl EnergySavr NO DONE YES 39130 4 040212 0 REFILL 155 DONE Adjusts the sensitivity of the refill circu...

Page 20: ...ispense is being performed Tank heaters are turned off and the unit will dispense for 1 minute to cool tank temperature ADJUSTMENTS OPTIONAL SETTINGS CONT 39130 4 040212 FACTORY DEFAULTS NO YES SERVIC...

Reviews: