Bunn AXIOM BREWWISE Series Installation & Operating Manual Download Page 14

Page 14

SPRAY OZ/M:     25.0

(-)         DONE        (+)

View or enter the actual flow rate coming out of the sprayhead.  
This is used to tell the internal controller how fast the water 
is flowing. Use the "CALIBRATE FLOW" screen to obtain the 
most current flow rate. 
Range: (3.0 to 75.0 oz) or (100 to 2200ml)

CALIBRATE FLOW  ?

NO                      YES

This function provides a 60 second test mode to capture water from 

each sprayhead. This measurement will then give you the numbers 

to enter into the "SPRAY OZ/M:  xx" screen (next) NOTE: Should be 

performed after deliming and/or changing sprayhead. 

(Will not display when "BrewLogic" is enabled)

This function allows the operator to test and enter the actual flow 

rate of the sprayhead(s) for each side of the brewer by dispensing 

each separately for one minute. The volumes are then entered into 

the brewer.

WARNING: The sprayhead(s) must be installed before proceeding!

Procedure to calibrate the sprayhead flow rate:

1.  Place a container, accurately graduated with a minimum capacity 

of 60 ounces, under the funnel.

2.  Press and hold the right hidden switch until the display reads 

"AXIOM - VERSION #.#". Press and release the right hidden switch 

until the display reads "CALIBRATE FLOW ?"

3.  Select "YES". The display should read "CONTAINER READY?" If 

container is under the funnel, select "YES".

4.  The display should read "CALIBRATE SPRAY". Press and release 

the "BREW" switch to begin the sprayhead flow for calibration. The 

display should read "CALIBRATE SPRAY...60 SEC TO FINISH. The 

60-second timer on the display will count down to zero. When 

the counter reaches zero, the display will change to "ENTER OZ      

25.0"

5.  Measure the amount of water in the container and use (-) and (+) 

to adjust the display to the amount in the container. Then select 

"DONE"

6.  The display should now read "NEW SPRAY FLOW" along with the 

correct flow rate of the sprayhead. After about 5 seconds, the 

display will return to the "CALIBRATE FLOW" screen.

7.  To exit the "CALIBRATE FLOW" function and advance to the next 

screen, select NO. To exit programming and return to the MAIN 

SCREEN, press "ENABLE BREW ON/OFF" switch.

8.  (TWINS) Repeat steps 1-7 to calibrate the other side.

CONTAINER READY  ?

QUIT                       YES

CALIBRATE SPRAY

PRESS BREW START

ENTER   OZ      25.0

(-)         DONE        (+)

NEW SPRAY FLOW:

25.0  OZ/M

ADJUSTMENTS & OPTIONAL SETTINGS (CONT.)

39130.4 040212

Summary of Contents for AXIOM BREWWISE Series

Page 1: ...ision of the Operating Manual or to view the Illustrated Parts Catalog Programming Manual or Service Manual please visit the Bunn O Matic website at www bunn com This is absolutely FREE and the quicke...

Page 2: ...es that are binding on BUNN Accordingly statements by such individuals whether oral or written do not constitute warranties and should not be relied upon If BUNN determines in its sole discretion that...

Page 3: ...applicable Plumb ing Sanitation Code for your area Optional Field Wiring 120 208 240 V 15 6 17 5 A 2980 3850 W 1PH 3 Wire GND 60HZ 29710 0007 37881 0002 INTRODUCTION This equipment will brew a 1 2 ga...

Page 4: ...k 10 Set voltage switch to the appropriate position and replace the access panel DV Models Only 11 If plumbing is to be hooked up later be sure the brewer is disconnected from the power source If plum...

Page 5: ...res Suitable For At Least 90 C 194 F FOR USE ONLY ON AN INDIVIDUAL BRANCH CIRCUIT RATED 20 AMPS Dual Voltage Switch in 120V position Dual Voltage Switch in 120 208 240V position 120 208 120 240V AC Si...

Page 6: ...unter top Bunn O Matic does not recommend the use of a saddle valve to install the brewer The size and shape of the hole made in the supply line by this type of device may restrict water flow 1 Insert...

Page 7: ...tip carefully remove the brew funnel and discard the grounds and filter 39130 4 040212 D A ENABLE BREW ON OFF SWITCH Pressingthe ENABLEBREWON OFF switch indicatoron supplies power to the brew station...

Page 8: ...problems in the brewer and takes less than a minute NOTE In the event that the Brew Logic circuit activates compensating for high lime build up it will temporarily disable the Recovery Booster and Pu...

Page 9: ...to their specifications PROGRAMMING SWITCHES 1 FUNCTION SCREEN This is the display which shows the various functions 2 Right of the display This is used to access the program mode and is also used to...

Page 10: ...DONE ENTER PASSWORD 0 0 0 BREW LOCKOUT NO DONE YES PROGRAMMING FUNCTIONS OVERVIEW BrewWIZARD EXITING BrewWIZARD UNITS METRIC DONE ENG SET LANGUAGE NO YES SET PASSWORD 0 0 0 ENTER SERVICE NO YES BREW O...

Page 11: ...xx xx FACTORY DEFAULTS NO YES SERVICE TOOLS NO YES BREW COUNTERS NO YES ENABLE BrewLOGIC NO DONE YES 0 REFILL 155 DONE ENABLE CLEAN NO DONE YES SET PULSE BREW NO YES ADJUSTMENTS OPTIONAL SETTINGS CON...

Page 12: ...o the MAIN SCREEN Always remember to place an empty server and funnel under the sprayhead when operating the brewer during the set up of PULSE BREW CALIBRATE FLOW and testing the brew valve in SER VIC...

Page 13: ...TTINGS CONT This function allows the operator to adjust the brew strength extraction time Setting 1 will produce a non pulsed brew cycle and the highest 14 will give you the longest time utilizing pul...

Page 14: ...right hidden switch until the display reads AXIOM VERSION Press and release the right hidden switch until the display reads CALIBRATE FLOW 3 Select YES The display should read CONTAINER READY If cont...

Page 15: ...ON OFF switch 10 The display will now read A with a flashing cursor below it Press and hold the SCROLL switchtoscrollthroughthealphabetandavail able characters When the desired character is shown on t...

Page 16: ...NE YES SCROL THRU ALPHA NEXT NEXT LETTER A SCROLL DONE NEXT WRITE BTM LINE NO YES SAVE NO EDIT YES ADVERTISEMENT SETUP COMPLETE ADJUSTMENTS OPTIONAL SETTINGS CONT ENTER SERVICE ENTER SERVICE ADVERTISE...

Page 17: ...red 5 Press and release the DONE switch The displaywillnowread EXITINGBrewWIZARD and then ENTER PASSWORD ENTER PASSWORD This function allows the operator to enter a 3 digit number to access LEVEL 2 If...

Page 18: ...O YES NOTE If the brewer is set for Metric Units displays will be different ex Brew oz will become Brew milliliters F will be C Adjusts brew tank temperature RANGE 185 to 205 F or 85 to 96 C This func...

Page 19: ...or reduce the tank temp to 140 F or 60 C once the set idle time has expired Range 0 5 24 0 hrs Enabl EnergySavr NO DONE YES 39130 4 040212 0 REFILL 155 DONE Adjusts the sensitivity of the refill circu...

Page 20: ...ispense is being performed Tank heaters are turned off and the unit will dispense for 1 minute to cool tank temperature ADJUSTMENTS OPTIONAL SETTINGS CONT 39130 4 040212 FACTORY DEFAULTS NO YES SERVIC...

Reviews: