Now slowly return the vacuum frame into its horizontal position. (If any displacement of the artwork
has occurred, reopen the frame and rearrange the artwork.)

Locate the switches, the timer, the ampere meter
and the vacuum control on the front panel of the
unit   (Hellas-E:   no   Amperemeter).   All   to   the   left,
there is a switch controlling the vacuum pump. Put
it into its ON position. The pump will start running
and   the   indicator   lamp   in   the   switch   will   light.
Within   a   few   seconds,   the   pump   will   have
evacuated the air between the frame and the glass
plate. The vacuum indicator will show approx. 0.8
bar.
The  polyester  foil  is   structured  to  allow  an  easy
and   complete   evacuation   on   the   whole   surface.
Nevertheless,  there  might   remain  an  air  cushion
between the artwork and the board. Wipe over the
polyester foil with your hand or with a soft cloth to remove any rest of air. Using the handle, smoothly
close the cover.

Select single or double side exposure by turning on the appropriate switches for the upper and lower
set of tubes. They are located to the right of the timer. Hellas-E: You may switch on only the upper
unit.
To start the exposure, follow the instructions below to operate the electronic timer. Alternatively you
can operate Hellas in continuous mode. To do so turn on the switch left to the timer.  Turn the switch
off  to stop the continuous operation mode. The indicator lamp in the switch is lit during automatic
exposure and continuous operation as well. The switch is marked ventilator to indicate that there is
a built-in fan  always  running  together  with the lower  tube set.   Hellas-E: there is no switch for
continuous exposure.

Timer

The exposure time is controlled by a digital-read-out and digital-adjustable timer. The range of time
is from 1 second to 9 minutes 59 seconds. The device supports easy time pre selection and recall
by one hand operation and can be run in stop-and-go turns.
On the timer front panel there are the LCD time display and the three buttons MODE, + and -.

To adjust the desired exposure time, press the + or - buttons accordingly. Keeping one of them
down makes the settings change faster.
To start exposure, press the MODE button once. The remaining time is displayed continuously on
the LCD display. The process is interrupted and restarted for the remaining time at each time the
MODE button is pressed. The timer beeps several times when exposure has finished.

To redisplay the previous setting, press the MODE button once. You may then use the +/- buttons to
change the setting or just restart the unit by pressing the MODE button. 
Do not switch off the vacuum during exposure! With the artwork loosing contact to the board, severe
under-cut may result.

When having completed the exposure, open the cover, switch off the vacuum and open the frame.
Never lift the frame with the vacuum pump running. Abnormal usage of the frame would result.

The intensity and spectre of the UV light from the fluorescent tubes can be compared to that of skin
tanning sets: It may irritate your eyes. You should therefore avoid to look directly into the light for a
longer time.

Hellas

Hellas-E

Bungard Elektronik GmbH & Co. KG, Rilkestraße 1, 51570 Windeck – Germany

Tel.: +49 (0) 2292/9 28 28 - 0, Fax: +49 (0) 2292/9 28 28 - 29, E-mail: [email protected]

Summary of Contents for Hellas E

Page 1: ... Technical Data 2 EG Declaration of Conformity 3 Intended Use 4 Safety instructions 4 Set Up 5 Operating 5 Spare Part List 7 Guarantee 8 Disclaimer of Warranty 8 Copyright 9 Bungard Elektronik GmbH Co KG Rilkestraße 1 51570 Windeck Germany Tel 49 0 2292 9 28 28 0 Fax 49 0 2292 9 28 28 29 E mail support bungard de ...

Page 2: ...nted illuminated switches Maintenance free all steel construction cover safety switch optional Applications With the vacuum Hellas unit you can process all photosensitive products with spectral sensitivity in the near UV range 360 400nm These are especially positive or negative photo coated pcbs printing plates made of nylon aluminum steel and diazo and transfer films Options Quick release button ...

Page 3: ...schinen Teil 1 Allgemeine Anforderungen Safety of machinery Electrical equipment of machines Part 1 General requirements DIN EN ISO 14121 1 Sicherheit von Maschinen Risikobeurteilung Teil 1 Leitsätze Safety of machinery Risk assessment Part 1 Principles DIN EN ISO 12100 1 Sicherheit von Maschinen Allgemeine Gestaltungsleitsätze Risikobeurteilung und Risikominderung Safety of machinery Basic concep...

Page 4: ...und the machine for operation and maintenance Do not place the device near heat sources such as radiators warm air ducts ovens and the like The installation environment is crucial for problem free work with the Hellas You must therefore place particular emphasis on a room that is as dust free as possible and room air free of corrosive vapors in order to ensure that it functions properly Electrical...

Page 5: ...form us and the carrier Remove the tape locking the cover and verify that the fluorescent tubes have not been damaged during transport To do so take the cover s handle and lift it so that the cover stands vertically on the rear mounted rubber pads Looking onto the lower part of the set you can see the vacuum frame with its polyester foil spanning over a crystal glass plate Please check the foil th...

Page 6: ... that there is a built in fan always running together with the lower tube set Hellas E there is no switch for continuous exposure Timer The exposure time is controlled by a digital read out and digital adjustable timer The range of time is from 1 second to 9 minutes 59 seconds The device supports easy time pre selection and recall by one hand operation and can be run in stop and go turns On the ti...

Page 7: ...their axis until they snap off from the fittings Replace them only with tubes of the same type and strength Check that the new tubes are well locked It is recommended also to replace the starters We want to tear your special attention to a careful maintenance of the vacuum foil It should be cleaned regularly using water and a soft detergent Do not use solvents Be extremely careful not to contamina...

Page 8: ...arent plastic sheet Guarantee All machines are submitted before distribution to examination on function and continuous operation firmness On the machine we grant a work warranty of 12 months to our customers starting from purchase date on accuracy in material and processing We warrant at our choice by exchange of incorrect parts or by repair of the machine in our house Old parts change into our po...

Page 9: ...mage or destruction of work pieces worked on in the machine because we have no knowledge or control over the operating conditions at your site This is valid in a general manner also for requirements from damage to articles buildings and persons as well as the environment We do not warrant that the function of the machine will meet the customer s requirements or that the operation of the machine wi...

Reviews: