cleaning
Follow the manufacturer's recommendations when cleaning the device.
vacuum
The thickness of the workpieces to be processed should not exceed 5 mm, as otherwise the
vacuum may be impaired or the vacuum film may even be damaged. For this reason, no sharp
objects may lie between the glass plate and the vacuum film when the vacuum is switched on.
Also make sure that the vacuum hose, which opens into the glass plate (Hellas-E: aluminum
plate) at the front left, is not blocked by objects.
work safety
Do not look into the UV lamps! Intended use is carried out in the closed state to avoid eye
injuries.
protect from moisture
Protect against falling
Only open the lid briefly for loading (prevent it from falling).
environmental Protection
Attention: Fluorescent tubes must be handled with care and disposed of as special waste
according to the rules of waste disposal. If the lamp breaks, be sure to consult your safety
officer and wear suitable protective clothing to avoid serious damage to health.
Set Up
The unit should be put onto a table in a way that it can be accessed from the front. Please keep a
distance of 30 cm from walls, radiators etc. and make sure that the cover can be easily opened up
to a vertical position.
If you encounter any transport damages be sure to directly inform us and the carrier.
Remove the tape locking the cover and verify that the fluorescent tubes have not been damaged
during transport. To do so, take the cover's handle and lift it so that the cover stands vertically on the
rear mounted rubber pads.
Looking onto the lower part of the set, you can see the vacuum frame with its polyester foil spanning
over a crystal glass plate. Please check the foil, the frame and the glass plate for any damage. You
may lift the frame vertically so that it leans against the upper part of the unit. Using a soft cloth,
please remove dirt or rests of packing material from the foil and the glass plate.
To check that the electrical components of the unit work correctly, please follow the operating
instructions given here below. The set requires a 230 V, 50 Hz main supply.
Operating
Put the cover and the vacuum frame into a vertical position. Place the board to be exposed onto the
glass plate. Be sure to have removed any protective foil from the board. Place the artwork onto the
board. For double sided boards, we propose that you mount the top and bottom artwork on an L-
shaped carrier so that they superimpose and form a "bag" with lateral stops for the board. You will
have best results with the emulsion side of the artwork (film) lying directly on the photoresist. Take
care not to enclose dust particles between the board and the artwork.
Bungard Elektronik GmbH & Co. KG, Rilkestraße 1, 51570 Windeck – Germany