background image

Page 1 / 8

Preface

Professsional equipment for laboratory pro-
totyping of through-hole plated PCBs up to 
210 x 300 mm size. Clean system including 
built-in   rinsing   compartment.   Maintenance 
free   and   made   for   easy   processing   and 
handling. This particular machine type is op-
timized in terms of space requirements and 
costs.   COMPACTA   30   is   suitable   for   the 
Dexter 3 D process (known on the market as 
the ABC chemical system).

Features:

Processing   sequence   for   the   ABC   panel 
plating (tenting) technique: 
Cleaner
Conditioner
Pre-dip
Catalyst
Salt remover
Copper plate

Equipment:

 

5 treatment tanks, 2 of them with heaters
1 galvanic copper bath 
1 triple-cascade rinse with flow control 
1 spray rinse tank with magnetic valve, foot 
switch and flow control 
1 free tank (i.e. for chemical tinning) 

Rectifier: 

1   Rectifier   for   copper   plating   6   V   /   40   A, 
seperate   current   and   voltage   display   and 
setting. Residual ripple < 0.1 % DCU 

Bath control: 

2   PTFE/PFA   coated   heaters,   controlled   by 
analogue instruments, full digital timers with 
count-down,   auto-reset   and   beeper.   Air  in-
jection   into   the   copper   plating   bath.   Board 
movement   by   DC   gear   motor,   adjustable 
speed.

Options:

Digital timers

Additional required equipment:

Chemicals,   anodes,   anodes   holder   and 
board holder

Technical Data

Dimensions
Treatment Tanks

Galvanic 
Tank

Lenght

400 mm

400 mm

Width

100 mm

300 mm

Depth

300 mm

300 mm

Content

ca. 10 l

ca. 30 l

Dimesions

(Width   x   Depth   x 
Height):   88   cm   x   100 
cm x 135 cm 

Working Height

95 cm

Weight

80 kg

Heating

2 x 400 W 

Rectifyer

1 x 6 V, 40 A 

Bath Movement

DC Gear Motor

Electrical   Con-
nection

220 V, 50 Hz, 6.3 A 

COMPACTA 30

Through hole plating machine

Instructions for use

Summary of Contents for COMPACTA 30

Page 1: ...witch and flow control 1 free tank i e for chemical tinning Rectifier 1 Rectifier for copper plating 6 V 40 A seperate current and voltage display and setting Residual ripple 0 1 DCU Bath control 2 PTFE PFA coated heaters controlled by analogue instruments full digital timers with count down auto reset and beeper Air in jection into the copper plating bath Board movement by DC gear motor adjustabl...

Page 2: ...our country 9 Follow the manufacturer s recommenda tions for cleaning the unit 10 If you are not going to use the unit for some time remove the plug from the socket 11 Take great care to ensure that no liquids or other foreign bodies can find their way in side the unit through the openings in the casing 12 The unit should only be repaired by qual ified personnel Never try to do more in the way of ...

Page 3: ...e switch disappears Timer Press MIN and Sec button at the same time to reset timer to zero Press MIN button to advance minute digits Press and hold MIN button for speed setting Press SEC button to advance second digits Press and hold SEC button for speed set ting After time setting is ready press STRART STOP once and timer will start to count down Battery replacement Follow the arrow direc tion to...

Page 4: ...ts indicate the heating process Upon reaching the desired temperature the light goes off Set the temperature of the tanks at the ther mostats as follows Bath 1 Cleaner Conditioner 65 C Bad 4 Salt Remove 45 C The remaining tanks operate at room tem perature 4 Let the the machine now run for 2 3 hours with heating switched on and then turn it off at the main switch The next day check the tanks for p...

Page 5: ...rmic reac tions We recommend to use sulphuric acid 36 instead of the 98 concentrate Anode preparation For proper copper plating results it is neces sary to run the anodes under working condi tions but with reduced current of 1 A dm For that reason fix a clean and well brushed PCB of 200 x 300 mm in a board holder Then mount the holder onto the agitation rod and screw it carefully Start air agitati...

Page 6: ...ray rinse The aim of bath 2 the Pre Dip is to protect the expensive catalyst in bath 3 from intru sion of both other chemicals and rinse water That is why you must not rinse after Pre Dip but you have to go directly to the following bath 3 With the oscillating frame still moving and the rectifier switched on and preset and the air agitation switched on you now fix the board over the galvanic plati...

Page 7: ...anical cleaning can lead to damage to the nozzle Operating panel The rectifiers are maintenance free with the exception of the fan An annual preventive inspection is advantageous This includes Inspection and cleaning of the fan Inspection of electrical connections Clean the contact surfaces of the DC con nections Note It is forbidden to constructive interfer ence of any kind to carry into the devi...

Page 8: ...Running the machine in corroding humid dusty extremely hot or explosive atmo sphere happens at the operator s own risk and responsibility We explicitly exclude any warranty for dam ages resulting from running the machine in in corroding humid dusty extremely hot or explosive atmosphere Copyright C 2009 Bungard Elektronik Electrical Circuit COMPACTA 30 Through hole plating machine Instructions for ...