RM4210 Wiring Guide
January 2019
9
Figure 1-2. Wiring Diagram - Single CP-Protected Coupon
If the coupon has
one
wire connecting it to the test station, connect both the red Test Cpn 1 wire and
the blue Test Cpn 2 from the RM4210 wiring harness to the test station where the coupon wire is
connected.
If the coupon has two wires connecting it to the test station, complete the following steps:
1.
Connect one of the coupon wires to one side of the switch on the test station. Connect the red
Test Cpn1
wire from the RM4210 wiring harness to the other side of the switch.
2.
Connect the blue
Test Cpn 2
wire from the RM4210 wiring harness to the point on the test
station where the second coupon wire is connected.
3.
Cap off the orange
AC Coupon
wire from the RM4210 wiring harness, as it is not used for this set
up.
To set up for this type of measurement on Bullhorn Web, complete the following: