Page 39
Bullfrog Spas Owner’s Manual
of the filter/skimmer cavity.
PROBLEM:
Jets are weaker than normal or do not
work at all, but in both cases the pump is running.
Cause: 1.
Jet handle(s) is partially or fully closed.
Solution:
Open jet handle(s).
Cause: 2.
Spa filter cartridge is dirty.
Solution:
See "Cleaning Your Filter" in this Owner's
Manual.
Cause: 3.
There is air trapped in the spa equipment or
its face piping.
Solution:
Open the air-bleed valve on each pump
housing and allow air to bleed out of system. Be sure
to tighten each air-bleed valve as soon as water starts
to flow out.
Cause: 4.
The Suction Fitting(s) are blocked.
Solution:
Remove any item or debris that is blocking
each Suction Fitting.
Cause: 5.
The JetZone Divider is not installed (This
only applies to spas that have two pumps).
Solution:
Re-install in the appropriate JetPak position.
(Warning: Running your spa without a JetZone Divider
can cause serious damage to your pump.)
Cause: 6.
Slice Valve is closed.
Solution:
Open Valve and secure with Valve Keeper.