Page 16
Bullfrog Spas Owner’s Manual
Pump 2 purges for 5 minutes at the beginning of each
filter cycle. The low speed of pump 1 runs during fil-
tration and the ozone sterilizer (if installed) will be en-
abled. If any button is pressed during filtering, the
ozone sterilizer (if installed) will be disabled for 30
minutes.
Temperature Display Inversion
Press the “Warmer” or “Cooler” button, then the “Jets 1”
button to invert display. Use the same sequence to
revert back to normal display.
Standby Mode
The spa can be disabled when the filter needs to be
serviced or when changing/servicing a JetPak™. Press
the “Warmer” or “Cooler” button, then the “Light” but-
ton, and the display will show “
StbY
.” All spa functions
will be disabled except for auxiliary freeze control.
Press any panel button to resume spa operation.
Freeze Protection
If the temperature sensors detect a drop to 40°F within
the heater, then pump 1 (and the heater if necessary)
will automatically activate to provide freeze protection.
The equipment stays on until the sensors detect that
the spa temperature has risen to within 15°F of the set
temperature. The pump will purge for 30 seconds to 2
minutes at the end of the freeze condition.
DIAGNOSTIC MESSAGES:
No Message on Display:
Power has been cut off to the
spa.
Action Required:
The control panel will be disabled
until power returns. Spa settings will be preserved for
30 days with a battery back-up.
“
OHH
”
on Display:
“Overheat” - The spa has shut
down. One of the sensors has detected 118°F at the
heater.
Action Required:
DO NOT ENTER THE WATER. Remove
the spa cover and allow water to cool. Once the heater
has cooled, reset by pushing any button. If spa does not
reset, shut off the power to the spa and call your
authorized Bullfrog Portable Spa Dealer.
“
OH5
”
on Display:
“Overheat” - The spa has shut
down. One of the sensors has detected that the spa
water is 110°F.
Action Required:
DO NOT ENTER THE WATER. Remove
the spa cover and allow water to cool. At 107°F, the spa
should automatically reset. If spa does not reset, shut
off the power to the spa and call your authorized
Bullfrog Portable Spa Dealer.
“
ICE
”
on Display:
“Ice” - Auxiliary Freeze Sensor
detects potential freeze condition.
Action Required:
No action required. The pumps will
automatically activate regardless of spa status.
Wiring Diagram: Deluxe Control System