Page 32
Bullfrog Spas Owner’s Manual
deposits (a white chalky material) soak cartridge(s) in a
one part muriatic acid to ten parts water solution. USE
A PLASTIC CONTAINER ONLY. Calcium deposits indicate
a high spa pH, which should be corrected.
5. CAUTION: Using a brush to clean a cartridge could
damage it. Bullfrog’s SpinClean™ filter cartridge
cleaners may be used and can be obtained from your
authorized Bullfrog Portable Spa Dealer.
6. Reinstall cartridge(s), basket and skimmer face-plate.
7. Press any button on the control pad to reset the
control system.
LIGHT BULB REPLACEMENT
To replace a burned out or defective light bulb,
complete the following steps:
1. Disconnect electrical power supply.
2. Remove the door to the Equipment Compartment.
3. Locate the back of the Spa Light Fixture (Fig. X).
4. Grasp the light bulb holder located on the back of
the Spa Light Fixture. Twist counter-clockwise to release
it from Spa Light Fixture. Pull light bulb holder out of
Spa Light Fixture.
5. Replace light bulb and reinstall light bulb holder into
Spa Light Fixture.
6. Replace door to Equipment Compartment and restore
the electrical power supply.
Note:
For alternate lighting systems contact your
authorized Bullfrog Spa Dealer for service.
OZONE STERILIZER REPLACEMENT
On the front of your Bullfrog Ozone Sterilizer (optional)
is an ozone indicator light (the Ozone Sterilzer is
located in the equipment compartment). This indicator
light will glow whenever ozone is being produced.
To verify that your Ozone Sterilizer is working properly,
check the indicator light when the filter pump is
running and only during a preprogrammed filter cycle,
making sure that the indicator light glows (do not check
the indicator light if you have activated the jets within
the previous 30 minutes - as a safety device, your
Ozone Sterilizer shuts down for 30 minutes after the
“Jets” button has been pressed).
If the indicator light does not glow when the filter pump
is running then your Sterilizer is not working properly.
When this occurs, take the following steps:
1. Disconnect electrical power supply.
2. Locate the Ozone Sterilizer (Fig. Y).
3. Unplug the Ozone Sterilizer's power supply cord from
your spa's Control Center.
4. Disconnect the output tubing from the Ozone
Sterilizer.
5. Remove the mounting screws that hold the Ozone
Sterilizer in place.
(Figure Y) Ozone Sterilizer Location
(Figure X) Light Bulb Location