The solution solenoid, which shuts off solution fl ow when the bail handle is released, is protected from debris by the in-line fi lter
assembly. The fi lter assembly is located at the rear of the machine on the left hand side, just under the solution tank. It is important
to check and clean the screened washer inside the assembly regularly to ensure proper solution fl ow. To open, unscrew the
assembly (Note that the cone of the washer is facing out toward the rear of the machine). Remove washer and rinse, reinsert
and screw assembly together, tightening by hand.
Overtightening with tools may damage the plastic threads.
A Fitting,
MGHT
B Screened
Washer
C
Hose Barb Insert
D Fitting,
FGHT
In-Line Solution Filter Assembly
Rear Squeegee
A Squeegee
B Star-shaped
knob
C Adjusting screw for angle adjustment
D Suction
hose
E Blade fastening latch
F Washers for caster height adjustment
G Caster Wheel
Axle
Cleaning the Squeegee
Check the squeegee
(A)
daily and clean
as necessary.
1. Pull off the suction hose
(D)
.
2. loosen the two star-shaped knobs
(B)
.
3. Remove the squeegee
(A)
.
Changing the Squeegee Blades
Check the inner and outer squeegee
blades on the squeegee
(A)
weekly for
signs of wear. The squeegee blades can
be reused by turning them (can be turned
for 4 total uses).
1. Pull off the suction hose
(D)
, loosen the
two star-shaped knobs
(B)
and remove
the squeegee.
2. Unlock the fastening device
(E)
and
remove the outer squeegee blade. Turn
the squeegee blade or install a new
one, as necessary. Change the inner
squeegee blade in the same way.
Factory
Cleaning
Equipment,
Inc.
800-793-3790