background image

Airflow Test with Airflow 

Indicator 

With the turbo-blower unit turned ON, 
breathing tube connected to turbo-
blower unit, and the filter / cartridge 
installed, place the upright- positioned 
Airflow Indicator onto the free end of the 
breathing tube.
If the Airflow Indicator “Bottom of the 
Ball” fails to rise completely above the Top 
EVA “Pass Line” on the Airflow Indicator 
Tube, then the turbo-blower unit could 
be malfunctioning, have a clogged or 
damaged filter / cartridge, low battery, or 
battery malfunction.
Do not use a turbo-blower unit that fails 
the airflow test. Failure to observe this 
warning could result in death or serious 
injury.
Ensure the air outlet holes in the Airflow 
Indicator are not blocked by your hand, 
or other obstructions during the Airflow 
Test.  Any hole blockage will give bad air 
flow results.
Confirm the ball, within the Airflow 
Indicator, moves freely in the tube and 
rests at the bottom of the tube when 
turned upright before testing begins.
Airflow indicator must be in an upright, 
vertical position for an accurate 
measurement during the entire testing.

Low Flow Alarm 

It is important to follow these steps to test the turbo-blower unit Low Flow 
Alarm prior to operation. 
1.  Install battery, filter / cartridge, and breathing tube on turbo-blower unit 

according to section Setup and 
Getting Started.

2.  Press and hold the button for two 

(2) seconds, confirmed by a short 
beep, to turn the turbo-blower ON.

3.  Cover the outlet end of the 

breathing tube with your hand to 
completely cut off airflow.

4.  With the breathing tube blocked, 

the turbo-blower unit will increase 
in speed for approximately 15 
seconds until it sounds the Low 
Flow Alarm. Refer to section Understanding Alarms. 

Cleaning, Storage, and Disposal 

The EVA Powered Air-Purifying Respirator (PAPR) system should be cleaned 
and inspected after each use and prior to storage. Detach the battery, 
breathing tube, and hood from the turbo-blower unit. Inspect all parts for 
damage or other signs of excessive wear. Replace all damaged parts prior to 
storage or next use.  

 WARNING

Any products recommended for cleaning, maintenance, or disinfection do not 
adversely affect the PAPR equipment unless otherwise noted. 
Use only approved cleaning agents to clean, maintain or disinfect the PAPR. 
Use of other products may damage the unit and affect its performance.

Cleaning/Disinfection 

•  The exterior of the filter / cartridge can be gently wiped down with a dry 

or damp cloth. Ensure water does not enter filter / cartridge. Replace wet 
filter / cartridges. 

•  Do not use gasoline, organic-based solvents, or chlorinated degreasing 

fluids. 

The following chemicals have been tested and approved as cleaning agents 
for the turbo-blower unit, belt, and battery. 
• Process NPD (1.256) from Steris 
• Spor Klenz (undiluted) from Steris 
• Clorox liquid bleach at 10% concentration 
• Sani-cloth HB wipes 
• 100% Methanol 
• 70% IPA
•  Mechanical laundering of hoods is not recommended. Hand-sponge with 

warm water and mild detergent if reusing. 

•  Ensure all equipment is clean and dry prior to storage and next use. 
•  Do not immerse the equipment in water or clean in an industrial/

respiratory dishwasher, unless using Bullard Decontamination Kit. See 
Bullard Decontamination Kit instructions for more detail.

Mild 

Detergent

Approved 

Cleaning 

Agents

Water 

Immersion

Respirator 

Washer

Battery

Yes

Yes

Belts / 

Backpacks

Yes

Yes

Yes

Yes

Breathing Tube

Yes

Yes

Yes

Turbo-blower 

Unit

Yes

Yes

Yes*

Yes*

Hood

Yes

Filter / Cartridge

Yes

* Use Bullard Decontamination and Storage Kit 

Decontamination Shower

If wearing the EVA Powered Air-Purifying Respirator (PAPR) system into a 
decontamination shower, filters should be left installed with a decon shower 
cap covering it and the turbo-blower unit kept running. User PAPRSC2 decon 
shower cap for filter/cartridge PAPRFC3 and PAPRSC3 decon shower cap for 
filter/cartridge PAPRFC4 and PAPRFC5.

Pass

Fail

www.bullard.com

9

EVA (with LF-Series and RT-Series Hoods)

Powered Air-Purifying Respirator (PAPR) System

Summary of Contents for 20LF2LHE

Page 1: ...EVA with LF Series and RT Series Hoods Powered Air Purifying Respirator PAPR System www bullard com ...

Page 2: ...e PAPR if low flow alarm has activated The PAPR is not permissible for use in an explosive atmosphere The PAPR contains electrical parts that may cause an ignition in flammable or explosive atmospheres Follow the manufacturer s user instructions for changing filters cartridges Never substitute modify add or omit parts Use only exact Bullard replacement parts in the configuration as specified by th...

Page 3: ...es Air Flow Indicator Breathing Tube EVA with Belt LF Series RT Series EVA Battery EVA Battery Charger PAPRFC3 PAPRFC4 PAPRFC5 Prefilters are available for both filter cartridge PAPRFC4 and PAPRFC5 and are optional in many situations Prefilters act by helping to block larger particulates from reaching the main filter which can help extend the usable life of the filter The prefilter PAPRPF2 must be...

Page 4: ...s holes or cracks The breathing tube should screw securely into the air source connection and the hood 6 Airflow Check The EVA Powered Air Purifying Respirator PAPR system is pre calibrated to ensure required airflow However the Airflow Indicator must be used to verify minimum required airflow is attained prior to each day s use The airflow should be checked with your current filter cartridge inst...

Page 5: ... Cartridge Installation a Remove the filter cartridge from its packaging and inspect for damage to the gasket and filtering media b Position the filter cartridge into the filter receptacle with the Bullard logo in the upright position Rotate the filter 1 8th of a turn clockwise until the filter lock tab is secure 4 Connecting the breathing tube a Ensure the rubber gasket is in place in the air sou...

Page 6: ... where the entire elasticized edge of the faceseal contacts your face For additional guidance refer to the LF Series Sizing Chart below to further match your face shape and head size If your proper fit falls between two 2 sizes default to the smaller size to ensure a snug fit www bullard com 6 Step 1 Face Shape Step 2 Head Diameter Option 1 hat size US size EU size Option 2 measure circumference a...

Page 7: ...urbo blower unit ON see Section 4 Operating Instructions within this manual 6 Don the hood according to the type of hood selected See LF Series Hood Donning Procedures or RT Series Hood Donning Procedures 7 Make any final adjustments to the fit as required to ensure a comfortable and stable fit Doffing Procedures 1 Prepare to doff the turbo blower battery and hood in a safe hazard free area It is ...

Page 8: ...ion may be required Operating Instructions The EVA Powered Air Purifying Respirator PAPR system has three 3 operating settings ON HIGH SPEED LOW SPEED OFF Operating Settings 1 ON HIGH SPEED Press and hold the button for two 2 seconds confirmed by a short beep to turn the turbo blower ON The turbo blower unit automatically turns ON at the high speed setting The turbo blower unit is designed to oper...

Page 9: ...hing tube and hood from the turbo blower unit Inspect all parts for damage or other signs of excessive wear Replace all damaged parts prior to storage or next use WARNING Any products recommended for cleaning maintenance or disinfection do not adversely affect the PAPR equipment unless otherwise noted Use only approved cleaning agents to clean maintain or disinfect the PAPR Use of other products m...

Page 10: ...gher temperatures the battery may not accept full charge If battery feels warm let it cool for 30 minutes before charging NOTE The turbo blower unit is provided with a circuit to protect the battery It will not allow the battery to be discharged below a safe voltage for the cells regardless of airflow without the Alarm sounding When the battery reaches the voltage cutoff it will automatically ceas...

Page 11: ...1 CFM Sound Pressure Level SPL 65 67 dBA SPL varies by system configuration and filter loading Audible Alarms Low battery Low airflow High temperature Low Battery Alarm 15 minutes remaining Low Flow Alarm If activated do not use PAPR Operating Temperature 5 C to 54 C 23 F to 129 F 90 RH Storage Conditions 5 C to 54 C 23 F to 129 F 90 RH Filter Storage Conditions 0ºC to 32ºC 32ºF to 90ºF 90 RH Turb...

Page 12: ...S DAMAGE OR ANY OTHER IMPROPER CARE OR HANDLING OF THE PRODUCT VOIDS THIS LIMITED WARRANTY The foregoing is the only warranty made by Bullard No representative dealer or any other person is authorized to make any warranty representation condition or promise on behalf of Bullard with respect to this product No terms or conditions other than those stated herein or provided by law and no agreement or...

Page 13: ...thing Tube Standard Length 26 EU Threads Medium PAHBTLEU EVA Breathing Tube XL Length 32 EU Threads Large PAHBTXLEU EVA Breathing Tube Standard Length 38 EU Threads X Large EVA Breathing Tube Covers Lenses RTLC RT Mylar Lens Cover Clear 25 Pack 20QCBTC EVA Breathing Tube Cover Tychem 2000 EVA PAPR Accessories EVABAT1 EVA Battery Black for Hoods EVABELT1 EVA Belt Standard Comfort Closed Cell Foam E...

Page 14: ...www bullard com 14 ...

Page 15: ...www bullard com 15 EVA with LF Series and RT Series Hoods Powered Air Purifying Respirator PAPR System ...

Page 16: ... Safety Way Cynthiana KY 41031 USA 877 BULLARD 285 5273 Tel 1 859 234 6616 Fax 1 859 234 8987 Bullard GmbH Dieselstrasse 8a 53424 Remagen Germany Tel 49 2642 999980 Fax 49 2642 9999829 Bullard Asia Pacific Pte Ltd 51 Changi Business Park Central 2 03 04The Signature Singapore 486066 Tel 65 6745 0556 Fax 65 6797 0299 INSPEC International B V Notified Body 2849 Beechavenue 54 62 1119 PW Schiphol Rij...