background image

www.bullard.com

5

EVA (with LF-Series and RT-Series Hoods)

Powered Air-Purifying Respirator (PAPR) System

2. Belt and Backpack Assembly 

a.  With the turbo-blower unit 

filter side down, orient the 
lever locks as shown. 

b.  Lay the belt over the turbo-

blower lever locks as shown. 

c.  Rotate the lever locks until 

they are oriented, as shown. 
Repeat steps in reverse order 
to remove the turbo-blower 
unit from the belt. 

d.  The EBH Backpack (optional 

accessory) requires the use 
of the belt. See EBH Backpack 
User Manual for assembly 
instructions. 

3. Filter / Cartridge Installation 

a.  Remove the filter / cartridge 

from its packaging and inspect 
for damage to the gasket and 
filtering media.

b.  Position the filter / cartridge 

into the filter receptacle with 
the Bullard logo in the upright 
position. Rotate the filter 1/8th 
of a turn clockwise until the 
filter lock tab is secure. 

4. Connecting the breathing tube 

a.  Ensure the rubber gasket 

is in place in the air source 
connection on the turbo-
blower unit. 

b.  Screw the black end of the 

breathing tube into the 
turbo-blower unit by turning 
clockwise. 

c.  Ensure that neither the 

breathing tube nor the hood 
connection is blocked. 

d.  Screw the blue end of the 

breathing tube into the 
blue hood connector on the 
back of the hood by turning 
clockwise.

a.

b.

c.

d.

Summary of Contents for 20LF2LHE

Page 1: ...EVA with LF Series and RT Series Hoods Powered Air Purifying Respirator PAPR System www bullard com ...

Page 2: ...e PAPR if low flow alarm has activated The PAPR is not permissible for use in an explosive atmosphere The PAPR contains electrical parts that may cause an ignition in flammable or explosive atmospheres Follow the manufacturer s user instructions for changing filters cartridges Never substitute modify add or omit parts Use only exact Bullard replacement parts in the configuration as specified by th...

Page 3: ...es Air Flow Indicator Breathing Tube EVA with Belt LF Series RT Series EVA Battery EVA Battery Charger PAPRFC3 PAPRFC4 PAPRFC5 Prefilters are available for both filter cartridge PAPRFC4 and PAPRFC5 and are optional in many situations Prefilters act by helping to block larger particulates from reaching the main filter which can help extend the usable life of the filter The prefilter PAPRPF2 must be...

Page 4: ...s holes or cracks The breathing tube should screw securely into the air source connection and the hood 6 Airflow Check The EVA Powered Air Purifying Respirator PAPR system is pre calibrated to ensure required airflow However the Airflow Indicator must be used to verify minimum required airflow is attained prior to each day s use The airflow should be checked with your current filter cartridge inst...

Page 5: ... Cartridge Installation a Remove the filter cartridge from its packaging and inspect for damage to the gasket and filtering media b Position the filter cartridge into the filter receptacle with the Bullard logo in the upright position Rotate the filter 1 8th of a turn clockwise until the filter lock tab is secure 4 Connecting the breathing tube a Ensure the rubber gasket is in place in the air sou...

Page 6: ... where the entire elasticized edge of the faceseal contacts your face For additional guidance refer to the LF Series Sizing Chart below to further match your face shape and head size If your proper fit falls between two 2 sizes default to the smaller size to ensure a snug fit www bullard com 6 Step 1 Face Shape Step 2 Head Diameter Option 1 hat size US size EU size Option 2 measure circumference a...

Page 7: ...urbo blower unit ON see Section 4 Operating Instructions within this manual 6 Don the hood according to the type of hood selected See LF Series Hood Donning Procedures or RT Series Hood Donning Procedures 7 Make any final adjustments to the fit as required to ensure a comfortable and stable fit Doffing Procedures 1 Prepare to doff the turbo blower battery and hood in a safe hazard free area It is ...

Page 8: ...ion may be required Operating Instructions The EVA Powered Air Purifying Respirator PAPR system has three 3 operating settings ON HIGH SPEED LOW SPEED OFF Operating Settings 1 ON HIGH SPEED Press and hold the button for two 2 seconds confirmed by a short beep to turn the turbo blower ON The turbo blower unit automatically turns ON at the high speed setting The turbo blower unit is designed to oper...

Page 9: ...hing tube and hood from the turbo blower unit Inspect all parts for damage or other signs of excessive wear Replace all damaged parts prior to storage or next use WARNING Any products recommended for cleaning maintenance or disinfection do not adversely affect the PAPR equipment unless otherwise noted Use only approved cleaning agents to clean maintain or disinfect the PAPR Use of other products m...

Page 10: ...gher temperatures the battery may not accept full charge If battery feels warm let it cool for 30 minutes before charging NOTE The turbo blower unit is provided with a circuit to protect the battery It will not allow the battery to be discharged below a safe voltage for the cells regardless of airflow without the Alarm sounding When the battery reaches the voltage cutoff it will automatically ceas...

Page 11: ...1 CFM Sound Pressure Level SPL 65 67 dBA SPL varies by system configuration and filter loading Audible Alarms Low battery Low airflow High temperature Low Battery Alarm 15 minutes remaining Low Flow Alarm If activated do not use PAPR Operating Temperature 5 C to 54 C 23 F to 129 F 90 RH Storage Conditions 5 C to 54 C 23 F to 129 F 90 RH Filter Storage Conditions 0ºC to 32ºC 32ºF to 90ºF 90 RH Turb...

Page 12: ...S DAMAGE OR ANY OTHER IMPROPER CARE OR HANDLING OF THE PRODUCT VOIDS THIS LIMITED WARRANTY The foregoing is the only warranty made by Bullard No representative dealer or any other person is authorized to make any warranty representation condition or promise on behalf of Bullard with respect to this product No terms or conditions other than those stated herein or provided by law and no agreement or...

Page 13: ...thing Tube Standard Length 26 EU Threads Medium PAHBTLEU EVA Breathing Tube XL Length 32 EU Threads Large PAHBTXLEU EVA Breathing Tube Standard Length 38 EU Threads X Large EVA Breathing Tube Covers Lenses RTLC RT Mylar Lens Cover Clear 25 Pack 20QCBTC EVA Breathing Tube Cover Tychem 2000 EVA PAPR Accessories EVABAT1 EVA Battery Black for Hoods EVABELT1 EVA Belt Standard Comfort Closed Cell Foam E...

Page 14: ...www bullard com 14 ...

Page 15: ...www bullard com 15 EVA with LF Series and RT Series Hoods Powered Air Purifying Respirator PAPR System ...

Page 16: ... Safety Way Cynthiana KY 41031 USA 877 BULLARD 285 5273 Tel 1 859 234 6616 Fax 1 859 234 8987 Bullard GmbH Dieselstrasse 8a 53424 Remagen Germany Tel 49 2642 999980 Fax 49 2642 9999829 Bullard Asia Pacific Pte Ltd 51 Changi Business Park Central 2 03 04The Signature Singapore 486066 Tel 65 6745 0556 Fax 65 6797 0299 INSPEC International B V Notified Body 2849 Beechavenue 54 62 1119 PW Schiphol Rij...

Reviews: