Servicing the VGA Kit
25
30. Viewing and Clearing the System Event Log (SEL)
WARNING
The System Event Log can only store up to 512 entries at a time.
Once this limit is reached, the LOG IS NOT AUTOMATICALLY EMPTIED to allow for the arrival
of new events. Beyond the 512-entry limit, NEW EVENTS ARE NOT RECORDED.
It is strongly recommended to empty this log regularly, using the Clear button, so that the
latest events can be logged.
Note that cleared entries are deleted and cannot be retrieved.
•
From the
Monitoring
tab, click
System Health
> System Event Log
to open the
System
Event Log
page.
-
Use the
Refresh
button to update the display at any time.
-
Use the
Clear
button to empty the log. Entries are deleted and cannot be retrieved.
Note
SEL messages and associated operation to recover are explained in the
NovaScale
9006 Service Guide
in the Troubleshooting the NovaScale 9006 Server Drawer
chapter.
31. Viewing Board and Security Messages
1. From the
Monitoring
tab, click
System Health > Messages
to open the
Board & Security
Messages
page.
2. Browse messages, as required, using the
Newer
and
Older
buttons.
mportant This log can record up to 1.000 events. Once this limit is reached, the
arrival of new messages will automatically delete the oldest messages in
the log.