Hot-swapping System Components
133
Determining Fan Failure
Each fan uses an amber LED to indicate the failed fan. The LED for each fan illuminates only
when a fan fails. When an LED illuminates the associated fan should be replaced. To view the
LEDs:
1.
See the warnings and cautions under
Removing and Installing the Top Cover
on page 126.
2.
Follow the instructions under
Removing the Top Cover
.
3.
Locate the fan bay. See
Figure 52
for location information.
4.
If a fan has failed, the LED for that fan will display an amber LED. See letter “A” in
Figure 59
for help in locating the LEDs.
5.
To replace a failed fan, see
Replacing a System Fan
. If no fan has failed, follow the
instructions under
Installing the Top Cover
.
Replacing a System Fan
Refer to
Figure 59
and use the instructions below to replace a hot-swap system fan:
1.
See the warnings and cautions under
Removing and Installing the Top Cover
on page 126.
2.
Follow the instructions under
Removing the Top Cover
.
3.
Follow the instructions under
Determining Fan Failure
to identify the failed fan.
4.
Place your fingers into the fan access points and squeeze your fingers together to release the
fan latch and remove the fan. See letter “B”
Figure 59
.
5.
Insert the replacement fan into place. It will fit only one way into the opening and will
easily click into place.
6.
Follow the instructions under
Installing the Top Cover
.
TP00318
A
B
A.
Fan LEDs (two of six pointed out)
B.
Access points
Figure 59. System Fan Location and Removal
Summary of Contents for NovaScale 4020
Page 1: ...Bull NovaScale 4020 User s Guide 86 A1 72EG 01 ORDER REFERENCE...
Page 2: ......
Page 62: ...46 NovaScale 4020 User s Guide...
Page 138: ...122 NovaScale 4020 User s Guide...
Page 144: ...128 NovaScale 4020 User s Guide...
Page 152: ...136 NovaScale 4020 User s Guide...
Page 158: ...142 NovaScale 4020 User s Guide...
Page 171: ......