Configuration Software and Utilities
107
Serial Channel Configuration
The serial channel is configured through the SMU. Set the connection mode to the desired
connection mode and the rest of the options to the desired state for your application.
•
Direct Connection Mode:
Set the options on the direct connection mode to the correct
states for your application. Disable the ping message to avoid receiving serial ping message
data from the BMC on your terminal screen.
•
Modem Connection Mode:
Set the options on the modem connection mode to the desired
states for your application. Disable the ping message to avoid receiving serial ping message
data from the BMC on your terminal screen.
Save the new serial channel configuration when you are done editing the serial channel settings.
Sample Setup for Terminal Mode
The following is an example of how to configure the console/host and server for Terminal
Mode. In this example, the console is running Windows 2000 with SP3. The console and
server are directly connected through the serial ports of both systems. See
Serial/Modem
Channel Configuration Sub-task
on page 70 for details about the Serial / Modem configuration
screens.
Server Configuration
1.
Run the SMU to configure the BMC.
2.
In the Navigation Pane at the left side of the SMU, click
Serial/Modem
to go to the
Serial/Modem configuration menu.
3.
At the
Connection Mode
box, pull down the menu and select
Direct Connect
Mode
.
4.
Select
Always Available
for the
Access Mode
.
5.
Select
Administrator
for the
Privilege Level Limit
.
6.
Select
None
for
Flow Control
.
7.
Leave the
Enable Data Terminal Ready
box unselected.
8.
Select
19200
for the
Baud Rate
.
9.
Click
Next
to move to the next menu.
10.
Click
Next
again to reach the Terminal Mode Configuration screen.
11.
Click in the
Enable Terminal Mode
box to select it.
12.
Click in the
Enable Line Editing
box to select it.
13.
Select
Backspace
for the
Delete Control
.
14.
Select the box for
Turn BMC echo of received characters on
.
15.
Select the box for
Enable handshake when BMC ready to receive
another message box
.
16.
Select
CRLF
for the
Newline output sequence (BMC to console)
box.
17.
Select
CR
for the
Newline input sequence (console to BMC)
box.
18.
Click
Save
to save your settings and click
Ok
to return to the Home page of the SMU.
19.
Click on the
User
option in the Navigation Pane to configure the user setup.
20.
Select the
Anonymous User
box and click on the
Edit
button to configure this user.
21.
In the Edit User Configuration screen, check the
Enable User
box.
22.
In the
Enter New Password
box, enter your password. In this example the password
is
guest
.
23.
Enter the password again in the
Verify New Password
box.
24.
Select
Administrator
for the
User Privilege Level
under the Serial/Modem
Channel menu.
Summary of Contents for NovaScale 4020
Page 1: ...Bull NovaScale 4020 User s Guide 86 A1 72EG 01 ORDER REFERENCE...
Page 2: ......
Page 62: ...46 NovaScale 4020 User s Guide...
Page 138: ...122 NovaScale 4020 User s Guide...
Page 144: ...128 NovaScale 4020 User s Guide...
Page 152: ...136 NovaScale 4020 User s Guide...
Page 158: ...142 NovaScale 4020 User s Guide...
Page 171: ......