Consideration
should
be
given
to
the
connection
of
the
equipment
to
the
supply
circuit,
so
that
overloading
of
circuits
does
not
compromise
the
rack
supply
wiring
or
over-current
protection.
To
provide
the
correct
power
connection
to
the
rack,
refer
to
the
rating
labels
located
on
the
equipment
installed
the
rack
to
determine
the
total
power
requirement
for
the
supply
circuit.
Do
not
install
this
unit
in
a
rack
where
the
internal
rack
ambient
temperatures
will
exceed
40
degrees
Celsius.
Do
not
install
this
unit
in
a
rack
where
the
air
flow
is
compromised.
To
ensure
proper
cooling,
place
the
unit
so
that
the
cooling
fan
exits
at
the
rear
of
the
unit
and
the
air
inlet
holes
at
the
front
of
the
unit
have
sufficient
clearance
to
ensure
airflow.
DANGER
An
electrical
outlet
that
is
not
correctly
wired
could
place
hazardous
voltage
on
metal
parts
of
the
system
or
the
products
that
attach
to
the
system.
It
is
the
customer’s
responsibility
to
ensure
that
the
outlet
is
correctly
wired
and
grounded
to
prevent
an
electrical
shock.
(RSFTD201)
CAUTION:
Ensure
that
all
rack-mounted
units
are
fastened
in
the
rack
frame.
Do
not
extend
or
exchange
any
rack-mounted
units
when
the
stabilizer
is
not
installed.
(RSFTC222)
CAUTION:
When
the
unit
is
extended,
its
weight
can
turn
over
a
rack
that
is
not
steady.
Before
you
pull
the
unit
out
of
the
rack,
ensure
that
a
rack
stabilizer
is
attached
to
the
bottom
front
of
the
rack.
Do
not
pull
out
more
than
one
unit
at
a
time.
The
rack
can
turn
over
if
you
pull
out
more
than
one
unit
at
a
time.
(RSFTC224)
Removing
and
Replacing
the
Cover
Attention:
This
procedure
is
intended
to
be
performed
only
by
an
IBM
authorized
service
representative.
Use
the
following
procedure
to
prepare
the
7214
Storage
Enclosure
for
removal
or
installation
of
a
storage
device.
Note:
Before
performing
this
procedure,
ensure
that
there
is
no
activity
on
the
SAS
cable
or
operations
being
performed
by
the
installed
devices.
Turning
off
the
7214
Storage
Enclosure
during
activity
on
the
bus
could
result
in
loss
of
data.
1.
Remove
any
media
from
the
installed
devices.
2.
Turn
off
the
power
to
the
7214
Storage
Enclosure.
3.
Remove
the
7214
Storage
Enclosure
from
the
host
system
configuration
(follow
the
procedure
in
the
7214
Model
1U2
Storage
Device
Enclosure
Setup
and
Operator
Guide).
20
7214
Storage
Device
Enclosure
Service
Guide
Summary of Contents for ESCALA 7214
Page 1: ...7214 Model 1U2 Storage Device Enclosure Service Guide ESCALA REFERENCE 86 A1 69EW 00...
Page 2: ......
Page 6: ...iv 7214 Storage Device Enclosure Service Guide...
Page 14: ...xii 7214 Storage Device Enclosure Service Guide...
Page 34: ...18 7214 Storage Device Enclosure Service Guide...
Page 50: ...34 7214 Storage Device Enclosure Service Guide...
Page 54: ...38 7214 Storage Device Enclosure Service Guide...
Page 56: ...40 7214 Storage Device Enclosure Service Guide...
Page 60: ...44 7214 Storage Device Enclosure Service Guide...
Page 66: ...50 7214 Storage Device Enclosure Service Guide...
Page 69: ......
Page 70: ...BULL CEDOC 357 AVENUE PATTON B P 20845 49008 ANGERS CEDEX 01 FRANCE REFERENCE 86 A1 69EW 00...