PROPANE GAS CONNECTIONS
CAUTION: Changing the gas tanks must be done away from any source of ignition.
LP Gas Tank must be marked in accordance with the Specifications for LP Gas Cylinders, Spheres and Tubes for
Transportation of Dangerous Goods and Commission LP Gas Tank connection device is compatible with outdoor cooking
appliances.
1)
LP Gas Tank has appropriate vapor withdrawal.
2)
LP Gas Tank must include a collar to protect the cylinder valve.
3)
LP Gas Tank uses a type 1 tank valve that is firmly
secured in an upright position.
4)
LP Gas pressure regulator and hose assembly supplied with this unit must be used without alteration and must be less
than 59 inches in length.
5)
If the hose assembly needs to be replaced, use only the type 1 specified in the parts list supplied with this unit. The
replacement hose assembly shall be that specified by the manufacturer.
6)
To connect, turn the black coupling nut of the hose and regulator assembly in a clockwise direction (see illustration below)
until it is completely threaded onto the cylinder valve before turning gas supply on. To remove turn the black coupling nut
of the hose and regulator assembly in a counter-clockwise direction.
7)
LP Gas Tank must have a listed overfilling prevention device
.
When installing a LP gas supply, the following criteria must be met:
1) LP cylinder must be marked in accordance with the Specifications for LP gas Cylinders,
Spheres and Tubes for Transportation of Dangerous Goods and Commission, CAN/CSAB339, as applicable.
2) Must have a listed overfilling prevention device.
3) A cylinder connection device compatible with the connection for outdoor cooking appliances.
4) The cylinder must be equipped with an arrangement for vapor withdrawal.
5) The cylinder must include a collar to protect the cylinder valve.