Appendix A. Check Commands for Customizable Services of Add_ons
57
> check_gamttraid -H <host> -P 0.0.1
GAMTT RAID PD OK
>
> check_gamttraid -H <host> -L 0.0
GAMTT RAID LD OK
>
> check_gamttraid -H <host> –v 1
GAMTT RAID OK
CT(Ct0) MegaRAID Ultra320-2x OK
CT(Ct1) DAC960FFX2 OK
CT(Ct2) MegaRAID Ultra320-2x OK
>
> check_gamttraid -H <host> -A 1 –v 1
GAMTT RAID CT OK
CT(Ct1) DAC960FFX2 OK
>
•
If global state is ”CRITICAL” or ”WARNING”, only concerned elements are displayed:
> check_gamttraid -H <host>
GAMTT RAID CRITICAL
CT(Ct0) MegaRAID Ultra320-2x CRITICAL
PD(Ct0 Ch0 Tg1) Disk Dead
>
> check_gamttraid -H <host> -L 0.1
GAMTT RAID LD CRITICAL
CT(Ct0) MegaRAID Ultra320-2x CRITICAL
LD(Ct0 Nu1) RAID5 Critical
>
•
If return code is ”UNKNOWN”:
> check_gamttraid -H <host>
GAMTT RAID UNKNOWN - snmp query timed out
>