7
Installation
The regulator connections are
3
/
4
" BSP female.
The connection to the appliance is
3
/
4
" BSP male.
(Refer to the „Specifications‟ section for the gas supply location dimensions).
NOTE: A Manual Isolation Valve must be fitted to the individual appliance supply line.
4.
Correctly locate the appliance into its final operating position and using a spirit level, adjust the legs
so that the unit is level and at the correct height.
5.
Connect the gas supply to the appliance. A suitable jointing compound which resists the
breakdown action of propane must be used on every gas line connection, unless compression fittings
are used.
6.
Check all gas connections for leakages.
WARNING:
DO NOT USE A NAKED FLAME TO CHECK FOR GAS LEAKAGES.
7.
Check that the gas operating pressure is as shown in the „Specifications‟ section.
NOTE:
The operating pressure is to be measured at the burner operating pressure test point outlet and with
one griddle burner operating at the “High Flame” setting.
8.
Turn off the mains gas supply and bleed the gas out of the appliance gas lines.
9.
Turn on the gas supply and the appliance.
10.
Verify the operating pressure remains correct.
Commissioning
1.
Before leaving the new installation;
a. Check the following functions in accordance with the operating instructions specified in the
„Operation‟ section of this manual.
• Light the Pilot Burner.
• Light the Main Burner.
• Turning 'Off' the Main Burner/Pilot.
b. Ensure that the operator has been instructed in the areas of correct lighting, operation, and
shutdown procedure for the appliance.
2.
This manual must be kept by the owner for future reference and a record of the Date of Purchase,
Date of Installation and the Serial Number of the Appliance must be recorded and kept with this
manual. (These details can be found on the Rating label, refer to the„Gas Connection‟ section).
NOTE:
If for some reason it is not possible to get the appliance to operate correctly, shut off the gas
supply and contact the supplier of this appliance.