Installation

 

 

Installation Requirements 

 

NOTE:

 

 

• 

It is most important that this appliance is installed correctly and that operation is correct before use.  

Installation shall comply with local gas, health and safety requirements. 

 

• 

This appliance shall be installed with sufficient ventilation to prevent the occurrence of unacceptable 

concentrations of substances harmful to health. 

 

Our Gas Griddles are designed to provide years of satisfactory service and correct installation is essential to 

achieve the best performance, efficiency and trouble-free operation. 
 
This appliance must be installed in accordance with National installation codes and in addition, in accordance 

with relevant National / Local codes covering gas and fire safety. 

 

United Kingdom: 

- Gas Safety (Installation & Use) Regulations 1998.

 

 

- BS6173

 

- Installation of Catering Appliances.

 

 

- BS5440

 

- 1 & 2 Installation Flueing & Ventilation.

 

Ireland:

 

- IS 820

 

- Non - Domestic Gas Installations.

 

 

Installations must be carried out by qualified persons only.  Failure to install equipment to the relevant 
codes and manufacturer‟s specifications shown in this section will void the warranty. 

 

Components having adjustments protected by the manufacturer are only to be adjusted by an authorised 
service agent. They are not to be adjusted by the installation person. 

 

Unpacking 

 

• 

Remove all packaging and transit protection from the appliance including all protective plastic coating from the 

exterior stainless steel panels. 

• 

Check equipment and parts for damage. Report any damage immediately to the carrier and distributor.

 

• 

Ensure that the 4 adjustable feet are fitted with the protruding centre screw. 

• 

Report any deficiencies to the distributor who supplied the appliance. 

• 

Check that the available gas supply is correct to that shown on the rating plate located on the right hand panel. 

 

Location 

 

1. 

Installation must allow for a sufficient flow of fresh air for the combustion air supply. 

 

Combustion Air Requirements:

 

 

CD963

 

CD964

 

GP518

 

Natural Gas (G20)

 

14.5 m

3

/hr

 

21.8 m

3

/hr

 

28 m

3

/hr

 

Natural Gas (G25) 

14.5 m

3

/hr 

21.8 m

3

/hr

 

 

Propane (G31)

 

15.0 m

3

/hr

 

22.5 m

3

/hr

 

29 m

3

/hr

 

 

2. 

Installation must include adequate ventilation means, to prevent dangerous build up of combustion 

products. 

3. 

Any gas burning appliance requires adequate clearance and ventilation for optimum and trouble-free 

operation. The minimum installation clearances shown below are to be adhered to. 

4. 

Position the appliance in its approximate working position. 

5. 

All air for burner combustion is supplied from underneath the unit.  The legs must always be fitted 

and no obstructions placed on the underside or around the base of the unit, as obstructions will 

cause incorrect operation and / or failure of the appliance. 

6. 

Components having adjustments protected by manufacturer are only allowed to be adjusted by an 

authorised service agent. They are not to be adjusted by the installation person. 

 

NOTE:  Do not obstruct or block the appliances flue.  Never directly connect a ventilation 

system to the appliance flue outlet.

 

Summary of Contents for CD963

Page 1: ...Gas Griddle Instruction Manual Model CD963 CD964...

Page 2: ...ts Unpacking Location Clearances Assembly Gas Connection Commissioning Operation 8 Operation Guide Description of Controls Lighting the Pilot Burner Lighting the Main Burner Cleaning and Maintenance 1...

Page 3: ...H READ THE INSTALLATION OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS APPLIANCE WARNING INSTRUCTIONS TO BE FOLLOWED IN THE EVENT THE USER SMELLS GAS ARE TO BE P...

Page 4: ...Gas Supply Requirements Natural Gas G20 Natural gas G25 Propane G31 CD963 CD964 CD963 CD964 CD963 CD964 Heat Input nett 14 Kw 21 Kw 14 Kw 21 Kw 14 Kw 21 Kw Gas Rate nett 1 45 m3 hr 2 2 m3 hr 1 7 m3 hr...

Page 5: ...4 Dimensions Dimensions for Bench Models CD963 CD964 544 0 610 0 69 5 744 395 330 101 5 441 0 804 5 804 5 441 0 101 5 330 395 744 69 5 849 0 915 0...

Page 6: ...coating from the exterior stainless steel panels Check equipment and parts for damage Report any damage immediately to the carrier and distributor Ensure that the 4 adjustable feet are fitted with th...

Page 7: ...his is correct for the gas supply the appliance is being installed for The gas conversion procedure is detailed in this manual b Supply Pressure required for this appliance is shown in the Specificati...

Page 8: ...e test point outlet and with one griddle burner operating at the High Flame setting 8 Turn off the mains gas supply and bleed the gas out of the appliance gas lines 9 Turn on the gas supply and the ap...

Page 9: ...These Gas Griddles have been designed to provide simplicity of operation and 100 safety protection 2 Improper operation is therefore almost impossible however bad operation practices can reduce the li...

Page 10: ...ate a single spark 3 Hold in the gas control knob for approximately 10 15 seconds then release The pilot burner should remain alight If not repeat these 3 steps 4 Pilot ignition can be viewed through...

Page 11: ...NOTE DO NOT use abrasive detergents strong solvents or caustic detergents as they could corrode or damage the griddle In order to prevent the forming of rust on the griddle plate ensure that any dete...

Page 12: ...s castings to cool and remove for cleaning NOTE In order to prevent the forming of rust on the griddle plate ensure that all detergent and cleaning material has been entirely removed after each cleani...

Page 13: ...Appliance Both of them can be found on the Rating label located on the appliance Fault Possible Cause Remedy Pilot won t light No gas supply Blocked pilot injector Ensure gas isolation valve is turne...

Page 14: ...e electrical connection lead from the rear of the piezo igniter fitted to the control panel 4 Unscrew and remove the injector A F from the main burner end clamp 5 Determine the correct injector size f...

Page 15: ...23mm A F from the regulator 3 Un clip the plastic pin from the cap rotate the pin and re fit it back to the cap the correct way for the gas type to be used Either LP or NAT should be visible on the f...

Page 16: ...or some reason it is not possible to get the appliance to operate correctly shut off the gas supply and contact the supplier of this appliance Gas Specifications Appliance Classification Category II2H...

Page 17: ...description and quote model number and serial number which is shown on the rating plate Gas Conversion Kits Part name Code QTY Categories Country CD963 CD964 Main injector 40 G25 Only 1470544 2 3 I2L...

Page 18: ...17 Explosion drawing...

Page 19: ...9 Regulable feet N A 4 10 Base plate CD963 N A 1 Base plate CD964 N A 1 11 Body ass y lower CD963 N A 1 Body assy lower CD964 N A 1 12 Regulator AC127 1 13 Back plate CD963 N A 1 Back plate CD964 N A...

Page 20: ...y Avonmouth Bristol BS11 8TB United Kingdom I the undersigned hereby declare that the equipment specified above conforms to the above Directive s and Standard s Ik de ondergetekende verklaar hierbij d...

Reviews: