Specifications 

 

 

Model Numbers Covered in this Specification

 

 

CD963 

Gas Griddle 610mm wide Bench Model.  

 

CD964 

Gas Griddle 915mm wide Bench Model.  

 

General

 

 

A commercial heavy duty, fully modular, gas fired griddle using a thermostatic burner system and 
fitted with stainless steel burners with full pilot and flame failure protection and piezo ignition. 
It uses a 19mm thick griddle smooth plate  

 

Pack Contents 
 

The following is included: 

 

BUFFALO Gas Griddle             

 

Regulator                         

 

Feet 

 

Instruction Manual 

 

Gas Supply Requirements

 

 

 

 

 

 

Natural Gas  (G20) 

Natural gas(G25) 

Propane(G31) 

CD963 

CD964 

CD963 

CD964 

CD963 

CD964 

Heat Input (nett) 

 14 Kw 

21 Kw 

 14 Kw 

 21 Kw 

 14 Kw 

 21 Kw 

Gas Rate (nett) 

1.45 m

3

/hr

 

2.2 m

3

/hr

 

1.7 m

3

/hr

 

2.5 m

3

/hr

 

1100 g/hr 

1630 g/hr 

Supply Pressure 

20mbar 

25mbar 

37&50mbar      

Burner Operating 
Pressure 

15mbar 

15mbar 

25mbar 

Gas Connection 

¾” BSP Male 

 

 

The burner operating pressure is to be measured at the gas control valve outlet test point withone griddle 

burner operating at „High‟ setting. The operating pressure is ex-factory set, through the appliance regulator 

and  not  to  be  adjusted,  apart  from  when  carrying  out  gas  conversion,  if  required.    (Refer  to  the  „Gas 

Conversion‟ section for details). 
 

 
 

Summary of Contents for CD963

Page 1: ...Gas Griddle Instruction Manual Model CD963 CD964...

Page 2: ...ts Unpacking Location Clearances Assembly Gas Connection Commissioning Operation 8 Operation Guide Description of Controls Lighting the Pilot Burner Lighting the Main Burner Cleaning and Maintenance 1...

Page 3: ...H READ THE INSTALLATION OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS APPLIANCE WARNING INSTRUCTIONS TO BE FOLLOWED IN THE EVENT THE USER SMELLS GAS ARE TO BE P...

Page 4: ...Gas Supply Requirements Natural Gas G20 Natural gas G25 Propane G31 CD963 CD964 CD963 CD964 CD963 CD964 Heat Input nett 14 Kw 21 Kw 14 Kw 21 Kw 14 Kw 21 Kw Gas Rate nett 1 45 m3 hr 2 2 m3 hr 1 7 m3 hr...

Page 5: ...4 Dimensions Dimensions for Bench Models CD963 CD964 544 0 610 0 69 5 744 395 330 101 5 441 0 804 5 804 5 441 0 101 5 330 395 744 69 5 849 0 915 0...

Page 6: ...coating from the exterior stainless steel panels Check equipment and parts for damage Report any damage immediately to the carrier and distributor Ensure that the 4 adjustable feet are fitted with th...

Page 7: ...his is correct for the gas supply the appliance is being installed for The gas conversion procedure is detailed in this manual b Supply Pressure required for this appliance is shown in the Specificati...

Page 8: ...e test point outlet and with one griddle burner operating at the High Flame setting 8 Turn off the mains gas supply and bleed the gas out of the appliance gas lines 9 Turn on the gas supply and the ap...

Page 9: ...These Gas Griddles have been designed to provide simplicity of operation and 100 safety protection 2 Improper operation is therefore almost impossible however bad operation practices can reduce the li...

Page 10: ...ate a single spark 3 Hold in the gas control knob for approximately 10 15 seconds then release The pilot burner should remain alight If not repeat these 3 steps 4 Pilot ignition can be viewed through...

Page 11: ...NOTE DO NOT use abrasive detergents strong solvents or caustic detergents as they could corrode or damage the griddle In order to prevent the forming of rust on the griddle plate ensure that any dete...

Page 12: ...s castings to cool and remove for cleaning NOTE In order to prevent the forming of rust on the griddle plate ensure that all detergent and cleaning material has been entirely removed after each cleani...

Page 13: ...Appliance Both of them can be found on the Rating label located on the appliance Fault Possible Cause Remedy Pilot won t light No gas supply Blocked pilot injector Ensure gas isolation valve is turne...

Page 14: ...e electrical connection lead from the rear of the piezo igniter fitted to the control panel 4 Unscrew and remove the injector A F from the main burner end clamp 5 Determine the correct injector size f...

Page 15: ...23mm A F from the regulator 3 Un clip the plastic pin from the cap rotate the pin and re fit it back to the cap the correct way for the gas type to be used Either LP or NAT should be visible on the f...

Page 16: ...or some reason it is not possible to get the appliance to operate correctly shut off the gas supply and contact the supplier of this appliance Gas Specifications Appliance Classification Category II2H...

Page 17: ...description and quote model number and serial number which is shown on the rating plate Gas Conversion Kits Part name Code QTY Categories Country CD963 CD964 Main injector 40 G25 Only 1470544 2 3 I2L...

Page 18: ...17 Explosion drawing...

Page 19: ...9 Regulable feet N A 4 10 Base plate CD963 N A 1 Base plate CD964 N A 1 11 Body ass y lower CD963 N A 1 Body assy lower CD964 N A 1 12 Regulator AC127 1 13 Back plate CD963 N A 1 Back plate CD964 N A...

Page 20: ...y Avonmouth Bristol BS11 8TB United Kingdom I the undersigned hereby declare that the equipment specified above conforms to the above Directive s and Standard s Ik de ondergetekende verklaar hierbij d...

Reviews: