Chapter 2 Configuration
- 21 -
Parameter
Meaning
VLANs
This displays the current VLAN configuration and PVIDs (Port VLAN
IDs).
The information displayed for each VLAN is the VLAN ID, port
membership attributes, PVID, VLAN name and VLAN Management.
You can also edit a VLAN by clicking
Edit
or delete it by clicking
Delete
.
You cannot delete VLAN 1.
ID
Specify the VLAN number.
Range: 1 to 4094
Name
Specify the VLAN name.
Up to 17 characters including only alphanumeric characters,
hyphens (-), and underscores (_).
Management VLAN
Specify a management VLAN. Only terminals connected to a
management VLAN can access Settings.
Tagged
Assign a port as a tagged member.
Untagged
Assign a port as an untagged member.
Not a Member
Indicates that the port as not been assigned as a member.
Restore
Reloads the current VLAN settings.
Clear
Clears the settings shown.
Privacy Separator
Enable or disable privacy separator (a function enabling
communication from each room to the router, but blocking
communication between rooms).
Uplink
Port used by the router to connect to the Internet. The Uplink port
can communicate with all Downlink ports.
Up to 2 ports can be selected at once.
Downlink
Connect to each room. Downlink ports can communicate with
uplink ports, but not with each other.
• If the VLAN ID of a received frame is not a VLAN member of the port on which it is received, it is
discarded by the ingress filter.
• If you set a port as Not Member from a certain VLAN, the PVID of the port must also be changed
from the VLAN ID.
(e.g., When you change Port 5 from VLAN 2 to Not Member, change the PVID to something other