PAGE 8
Current Adjustment
Current adjustment is on the front panel of the machine. It has infinite current output adjustment from 20 to
75 Amps.
Positive Output Connector
This is the connector for the electrode holder and cable, most often, when STICK welding. When this
machine is used for TIG welding, this connector is for the grounding cable.
Negative Output Connector
This is the connector for the ground cable and clamp, most often, when STICK welding. When this machine
is used for TIG welding, this connector is for the TIG torch.
Ground Cable and Clamp
The ground cable and clamp are attached to the work piece to complete the circuit allowing the flow of current
needed to weld.
Welding Cable and Electrode Holder
One end of the cable is connected to the output connectors of the welder. The electrode is held in the
electrode holder for welding.
Power Cord
The power cord connects the welder to the 120V volt power supply.
Plug the 15 amp plug into a
115V/20Amp receptacle to supply power to the welder.
INSTALLATION
1. POWER REQUIREMENT - AC single phase 120V (110-120V), 60 HZ with a 20 amp circuit breaker is
required. DO NOT OPERATE THIS UNIT if the ACTUAL power source voltage is less than 105 volts AC or
greater than 132 volts AC.
•
High voltage danger from power source! Consult a qualified electrician for proper
installation of receptacle. This welder must be grounded while in use to protect the
operator from electrical shock.
•
Do not remove grounding prong or alter the plug in any way. Do not use any adapters between the
welder's power cord and the power source receptacle. Make sure the
POWER switch is OFF when connecting your welder's power cord to a properly grounded
120 VAC, 60 HZ, Single Phase, 20 Amp input power supply.
2.
EXTENSION CORD
- We do not recommend an extension cord because of the voltage drop they
produce. This drop in voltage can affect the performance of the welder. If you need to use an extension cord,
we recommend you check with a qualified electrician and your local electrical codes for your specific area. Do
not use an extension cord over 25 ft. in length.