7-52
2002 Buell X1: Electrical
HOME
TROUBLESHOOTING
1.
If the horn does not sound or fails to function satisfacto-
rily, check for the following conditions:
a.
Discharged battery.
b.
Loose, frayed or damaged wiring leading to horn ter-
minal.
2.
If battery has a satisfactory charge and wiring appears to
be in good condition, test horn grounds and switch using
voltmeter.
a.
See
Figure 7-69.
Remove Y/BK power and BK
ground wires from terminal clips.
b.
Connect voltmeter positive (+) lead to Y/BK wire.
c.
Connect voltmeter negative (–) lead to ground.
d.
Turn ignition key switch to IGN.
3.
See
Figure 7-70.
Depress horn switch and observe volt-
meter reading.
a.
If battery voltage is present, horn or horn grounding
is faulty. If horn is faulty, replace unit as an assem-
bly. The horn is not repairable.
b.
If battery voltage is not present, either horn switch or
wiring to horn is faulty. If horn switch is faulty,
replace left handlebar switch. See
7.15 HANDLE-
BAR SWITCHES
.
Figure 7-70. Horn Switch
6981
Horn Switch
Summary of Contents for 2002 X1