![Buderus SM400/5E Installation And Maintenance Instructions Manual Download Page 22](http://html.mh-extra.com/html/buderus/sm400-5e/sm400-5e_installation-and-maintenance-instructions-manual_2826347022.webp)
3
Regulations
SU300/5 | SU400/5 – 6 720 800 019 (2015/04)
22
2.5
Product description
3
Regulations
Observe the following directives and standards:
• Local regulations
•
EnEG
(in Germany)
•
EnEV
(in Germany)
Installation of, and equipment for, heating and water heating systems:
•
DIN
and
EN
standards
–
DIN 4753-1
– Water heaters ...; requirements, identification,
equipment and testing
–
DIN 4753-3
– Water heaters ...; corrosion protection on the
water side through enamel coating; requirements and testing
(product standard)
–
DIN 4753-6
– Water heating systems ...; cathodic corrosion
protection for enamelled steel cylinders; requirements and
testing (product standard)
–
DIN 4753-8
– Water heaters ..., part 8: Thermal insulation of
DHW cylinders up to 1000 l nominal capacity – requirements and
testing (product standard)
–
DIN EN 12897
– Water supply - regulation for... DHW cylinders
(product standard)
–
DIN 1988
– Technical rules for potable water installations
–
DIN EN 1717
– Protection of potable water against
contamination...
–
DIN EN 806
– Technical rules for potable water installations
–
DIN 4708
– Central DHW heating systems
•
DVGW
– Code of practice W 551 – Potable water heating systems and
pipework; technical measures to inhibit the growth of legionella
bacteria in new systems;...
– Code of Practice W 553 – Sizing DHW circulation systems... .
4
Transport
▶ When handling, prevent DHW cylinders from falling.
▶ Move packed DHW cylinder with a sack trolley and strap (
-or-
▶ Move unpacked DHW cylinder with a transport net; during handling,
protect connections against possible damage.
5
Installation
The DHW cylinder is delivered as a fully assembled unit.
▶ Check that the DHW cylinder is complete and undamaged.
5.1
Siting
5.1.1
Installation site requirements
▶ Site the DHW cylinder on a plinth if there is a risk that water may
collect at the installation site.
▶ Site the DHW cylinder in dry internal areas that are free from the risk
of frost.
▶ Observe the minimum room height (
Table 4, page 21) and
minimum wall clearances inside the installation room
(
Fig. 6, page 106).
5.1.2
Positioning the DHW cylinder
▶ Stand the DHW cylinder upright and level it (
▶ Remove protective caps (
▶ Apply Teflon tape or Teflon string (
Continuous output (at 80 °C flow temperature, 45 °C DHW outlet temperature and 10 °C cold water
temperature)
kW
l/min
36,5
897
56
1376
Heat-up time at rated output
min
12
19
Maximum heat input
5)
kW
36,5
56
Maximum heating water temperature
°C
160
160
Max. heating water operating pressure
bar (positive)
16
16
Connection size, heating water
DN
R1"
R1"
Pressure loss diagram
Fig.
, page
1) Without solar heating or reheating; selected cylinder temperature 60 °C
2) Mixed water at the draw-off point (at 10 °C cold water temperature)
3) Distribution losses outside the buffer cylinder are not taken into account.
4) The performance factor NL=1 to DIN 4708 for 3.5 occupants, standard bath tub and kitchen sink. Temperatures: cylinder 60 °C, outlet 45 °C and cold water 10 °C. Measured
at max. heat input. The N
L
drops with reduced heat input.
5) Limit to the stated value for heat sources with higher heat input.
Unit
SM300/5
SM400/5(E)
Table 4 Dimensions and specification (
Fig. 1, page 104 and Fig. 3, page 105)
Pos. Description
1
DHW outlet
2
Cylinder flow
3
Sensor well for temperature sensor, heat source
4
DHW circulation connection
5
Cylinder return
6
Cold water inlet
7
Inspection apertures for service and cleaning at the front
8
Indirect coil for reheating by the boiler, enamelled smooth tube
9
Cylinder, enamelled steel
10
Fitted magnesium anode without electrical insulation
11
PS casing lid
12
Casing, painted sheet metal with rigid polyurethane foam
insulation, 50 mm
Table 5 Product description (
page 108)
NOTICE:
System damage through inadequate load
bearing capacity of the supporting surface or unsuitable
substrate.
▶ Ensure that the installation area is level and offers
sufficient load-bearing capacity.
Summary of Contents for SM400/5E
Page 113: ...9 Обслуговування SU300 5 SU400 5 6 720 800 019 2015 04 113 ...
Page 114: ...9 Обслуговування SU300 5 SU400 5 6 720 800 019 2015 04 114 ...
Page 115: ...9 Обслуговування SU300 5 SU400 5 6 720 800 019 2015 04 115 ...
Page 116: ...Bosch Thermotechnik GmbH Sophienstrasse 30 32 D 35576 Wetzlar www buderus com ...