3
Regulations
Logalux – 6721814241 (2020/03)
41
2.5
Technical Data
Table 50 Technical Data
2.6
Product data for energy consumption
The following product data satisfy the requirements of the EU
Regulations No. 811/2013 and No. 812/2013 supplementing EU
Regulation 2017/1369.
Manufacturers who implement these guidelines and state the ErP values
are permitted to use the "CE" mark.
Table 51 Product data for energy consumption
3
Regulations
Observe the following guidelines and standards:
• Local regulations
•
EnEG (Building Regulations)
(in Germany)
•
EnEV
(in Germany)
Installation of, and equipment for, heating and water heating systems:
•
DIN
and
EN
standards
–
DIN 4753-1
– Water heaters ...; requirements, identification,
equipment and testing
–
DIN 4753-3
– Water heaters ...; corrosion protection on the
water side with glass lining; requirements and testing
(product standard)
–
DIN 4753-7
– Water heaters, containers with a volume up to
1000 l, manufacturing, thermal insulation and corrosion
protection requirements
–
DIN EN 12897
– Water supply - regulation for ... DHW cylinders
(product standard)
–
DIN 1988-100
– Technical rules for potable water installations
–
DIN EN 1717
– Protection of potable water against pollution ...
–
DIN EN 806-5
– Technical rules for potable water installations
–
DIN 4708
– Central water heating systems
•
DVGW
– Code of Practise W 551 – Potable water heating systems and
pipework; technical measures to inhibit the growth of legionella
bacteria in new systems; ...
– Code of Practise W 553 – Sizing DHW circulation systems ...
Product data for energy consumption
•
EU Regulation
and
Directives
–
EU Regulation 2017/1369
–
EU Regulation 811/2013
and
812/2013
Unit
SU400.5
Dimensions and specifications
-
Fig. 2,
Pressure drop diagram
-
Fig. 3,
General description
Tilt height
mm
1955
Minimum room height for anode
replacement
mm
2100
Connection size, DHW
DN
R1"
Connection size, cold water
DN
R1"
Connection size, circulation
DN
R¾ "
Inner diameter, test point, cylinder
temperature sensor
mm
19.5
Inside diameter of handhole cover
mm
120
Cylinder capacity
Useful capacity (overall)
l
375
Usable DHW volume
1)
with DHW outlet
temperature
2)
:
1) Without solar thermal heating or recharging; set cylinder temperature 60 °C.
2) Mixed water at draw-off point (at 10 °C cold water temperature).
45 °C
l
536
40 °C
l
625
Standby heat loss (24 h) in accordance with
DIN 4753 Part 8
3)
3) Distribution losses outside the DHW cylinder are not taken into account.
kWh/24 h
1.7
Maximum flow rate at cold water inlet
l/min
38
Maximum DHW temperature
°C
95
Maximum operating pressure, potable water
bar
(positive)
10
Maximum DHW test pressure
bar
(positive)
10
Heat Exchanger
Content
l
12.0
Surface area
m
2
1.8
Rating code N
L
according to DIN 4708
4)
4) The rating code N
L
=1 according to DIN 4708 for 3.5 persons, standard bath tub
and kitchen sink. Temperatures: cylinder 60 °C, DHW outlet temperature 45 °C
and cold water 10 °C. Measured at max. heat output. If the heat output is
reduced, N
L
becomes smaller.
N
L
13
Continuous output (at 80 °C flow
temperature, 45 °C DHW outlet temperature
and 10 °C cold water temperature)
kW
l/min
54.5
22
Heating water volumetric flow rate
l/h
3500
Heat-up time at rated output
min
41
Maximum heat input
5)
5) In the case of heat sources with a higher heat output, limit to the stated value.
KW
54.5
Maximum heating water temperature
°C
160
Maximum operating pressure of heating
water
bar
(positive)
16
Connection size, heating water
DN
R1”
Product
number
Product type
Cylinder
volume (V)
Heat
retention
loss (S)
Energy
efficiency
class for
DHW
treatment
8732929605 SU400.5 S-B
375,0 l
69,9 W
B
Summary of Contents for Logalux S120/5 W
Page 54: ...Logalux 6721814241 2020 03 54 1 0010032917 001 1 7 8 9 10 11 12 2 4 5 6 3...
Page 59: ...Logalux 6721814241 2020 03 59 14 15 0010032921 001 1 2 0010032922 001 16 17 0010032923 001...
Page 60: ...Logalux 6721814241 2020 03 60 18 19 0010032924 001 1 20 21 0010032933 001 1 2 0010032934 001...
Page 61: ...Logalux 6721814241 2020 03 61 22 23 24 25...
Page 63: ...Logalux 6721814241 2020 03 63 29 30 0010032899 001 1 1 2 3 0010032900 001...
Page 64: ...Bosch Thermotechnik GmbH Sophienstrasse 30 32 D 35576 Wetzlar www bosch thermotechnology com...