Description 

 

The Buckleys Surface Display Pro’ Unit (SDU) has been designed to provide a 
remote  method of  verifying  the  corrosion potential voltage readings of  the 
Buckleys BathyCorrometer

® 

Pro’. 

 

The  SDU  (typically  aboard  a  vessel  or  on  a  platform) is connected  to  the 
BathyCorrometer

® 

Pro’ (used by a diver subsea) via a robust, two-core, water 

resistant umbilical cable of suitable length (supplied separately). 

 

Using a  4-20mA  signal,  the  voltage reading on  the  BathyCorrometer

®  

Pro’ is 

mirrored on the Surface Display Pro’, allowing quick and easy verification. 

 

Note: The voltage is now displayed as a negative voltage rather than positive 
as with early SDUs and Roxby/Buckleys BathyCorrometer

®

s. This has been 

changed to bring the readings in line with those widely used in the industry. 

Note: 

Using  the  surface  display  unit  with  a  different  BathyCorrometer

®  

Pro’  than  the  one  it  was  configured  for  may  cause  spurious  readings. 
See certificate supplied separately. 

 

The Surface Display Pro’ is fully compatible with the BathyCorrometer

®

  Mk5, 

however it is not suitable for use with older Roxby unit or early Buckleys BCMs. 

 

BathyCorrometer

®

  probe tip                 ON/OFF switch               Umbilical connection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mains power input

 

INPUT VOLTAGE 

SELECTOR

 

 

 

Summary of Contents for 6004-0079

Page 1: ...ss MANUFACTURERS OF SPECIALIST TEST EQUIPMENT Surface Display Pro Operating Instructions English Version Please read carefully before use...

Page 2: ......

Page 3: ...osal Information 8 EC Declaration of Conformity 9 UKCA Declaration of Conformity 10 Contact Details 11 Attention Misuse or failure to comply with the guidelines outlined in this manual may impair the...

Page 4: ...urface Display Pro allowing quick and easy verification Note The voltage is now displayed as a negative voltage rather than positive as with early SDUs and Roxby Buckleys BathyCorrometer s This has be...

Page 5: ...r However as with any mains powered device it is advisable to take a few basic precautions to minimize any risk still further Under no circumstances should the case of the SDU be opened If the unit sh...

Page 6: ...the SDU and BathyCorrometer Pro before the commencement of each corrosion survey Connect the SDU to the BathyCorrometer Pro using the two core water resistant cable that is to be used during the surv...

Page 7: ...upplied Plug the supplied mains power lead into the SDU checking that the mains input voltage selector is in the correct position do not connect the mains supply at this stage Use a small flat bladed...

Page 8: ...Buckleys Surface Display Pro has been designed so that no maintenance is required by the user The Surface Display Pro should be inspected from time to time to check that the case calibration leads an...

Page 9: ...ormity We Buckleys UVRAL Ltd As manufacturer of the apparatus listed declare that the product Surface Display Pro Unit Is manufactured in conformity with European directives 2014 30 EU 2014 35 EU Auth...

Page 10: ...cturer of the apparatus listed declare that the product Surface Display Pro Unit Is manufactured in conformity with the following UK legislation Electronic Compatibility Regulations 2016 The Electrica...

Page 11: ...t details Manufacturer Buckleys UVRAL Ltd Address Buckleys House Unit G Concept Court Shearway Business Park Shearway Road Folkestone Kent CT19 4RG UK Tel 44 0 1303 278888 Website www buckleysinternat...

Page 12: ...ating to your product Be the first to hear about our new products We strive to improve the quality of our products and service Registering your product helps us monitor overall quality of our products...

Reviews: