B T L - 5 0 0 0 S E R I E S
U S E R ' S M A N U A L
p a g e 5 1 o f 5 6
Type:
5820SL
5825SL 5820L 5825L 5830L 5835L 5840S 5840SL 5840L 5860L
Number
of
therapies
4 4 3 3 4 4 5 6 5 7
Electrotherapy
2 2 2 2 3 3 4 4 4 6
Ultrasound
therapy
1 1 1 1
Laser
therapy
1 1 1 1 1 1 1 1 1
Patient cardfile (positions)
min. 150
min. 150
min. 150
min. 150
min. 150
min. 150
min. 150
min. 150
min. 150
min. 150
User programs
min. 150
min. 150
min. 150
min. 150
min. 150
min. 150
min. 150
min. 150
min. 150
min. 150
User sequences
min. 50
min. 50
min. 50
min. 50
min. 50
min. 50
min. 50
min. 50
min. 50
min. 50
Step of setting of values
standard standard standard
standard
standard
standard
standard
standard standard standard
Encyclopaedia
x x x x x x x x x x
Preset
diagnoses
Preset
programs
Preset
sequences
Programs
Interconnection
with
PC
optional optional optional optional optional optional optional optional optional optional
optional optional optional optional optional optional optional optional optional optional
Language
versions
x x x x x x x x x x
Sound
schemes
x x x x x x x x x x
Display, diagonal
b/w
14.6 cm
b/w
14.6 cm
b/w
14.6 cm
b/w
14.6 cm
b/w
14.6 cm
b/w
14.6 cm
b/w
14.6 cm
b/w
14.6 cm
b/w
14.6 cm
b/w
14.6 cm
Screen saver
x x x x x x x x x x
Colour schemes
Recent
performed
therapies 20 20 20 20 20 20 20 20 20 20
Electro parameters:
Channel mode
CC / CV
CC / CV
CC / CV
CC / CV
CC / CV
CC / CV
CC / CV
CC / CV
CC / CV
CC / CV
Galvanic,
Iontophoresis
x x x x x x x x x x
Träbert,
Farad,
Neofarad x x x x x x x x x x
Diadynamics
x x x x x x x x x x
TENS
x x x x x x x x x x
Rectangular
pulses
x x x x x x x x x x
Triangular
pulses
x x x x x x x x x x
Exponential
pulses
x x x x x x x x x x
Combined
pulses
x x x x x x x x x x
Interrupted
pulses
x x x x x x x
Pulse modulation:
x x x x x x x x x x
random
frequency
sweep
x x x x x x x x x x
burst,
surges
x x x x x x x x x x
Stimulation
pulses
x x x x x x x x x x
Russian
stimulation
x x x x x x x x x x
2-pole
interference
x x x x x x x x x x
4-pole
interference
x x x x x x x x x x
Isoplanar
field
(interference)
x x x x x x x
Vector
field
(interference) x x x x x x x
Electrodiagnostics:
x x x x x x x
I/t curve (memory position)
min. 50
min. 50
min. 50
min. 50
min. 50
min. 50
min. 50
HVT
optional
H
–
waves
x x x x x x x
Spastic
currents
x x x x
Microcurrents
x x x x x x x
Leduc's
current
x x x x x x x
Mid-frequency
surges
x x x x
Ultrasound parameters:
Head of 4 cm
2
, 1 and 3 MHz
x
x
x
x
Head of 1 cm
2
, 1 and 3 MHz
optional
optional
optional
optional
Detection of contact
continuou
s
continuou
s
continuou
s
continuou
s
Continuous
operation
mode
x x x x
Pulse
operation
mode
x x x x
Duty
factor
x x x x
Laser parameters:
Max. laser output, 685 nm
50 mW
50 mW
50 mW
50 mW
50 mW
50 mW
50 mW
50 mW
50 mW
Max. laser output, 830 nm
400 mW
400 mW
400 mW
400 mW
400 mW
400 mW
400 mW
400 mW
400 mW
Continuous
operation
mode
x x x x x x x x x
Pulse
operation
mode
x x x x x x x x x
Duty
factor
x x x x x x x x x
Nogier
frequencies
x x x x x x x x x
EAV
frequencies
x x x x x x x x x