background image

3

1

5

7

4

6

8

A

B

C

D

M

Q1

MAN

BC

2

C1

SE

S1

(ii)

(ii)

(i)

S2

3

1

5

7

4

6

8

A

B

C

D

M

Q1

MAN

BC

2

S1

(ii)

(ii)

(i)

S2

3

1

5

7

4

6

8

A

B

C

D

M

Q1

MAN

BC

2

24

14

Wh

Wh

22

12

Rd

Rd

Bk

Bk

21

11

E

D

3

1

5

7

4

6

8

A

B

C

D

M

Q1

MAN

BC

2

C1

SE

S1

(ii)

(ii)

(i)

S2

3

1

5

7

4

6

8

A

B

C

D

M

Q1

MAN

BC

2

S1

(ii)

(ii)

(i)

S2

3

1

5

7

4

6

8

A

B

C

D

M

Q1

MAN

BC

2

24

14

Wh

Wh

22

12

Rd

Rd

Bk

Bk

21

11

E

D

3

1

5

7

4

6

8

A

B

C

D

M

Q1

MAN

BC

2

C1

SE

S1

(ii)

(ii)

(i)

S2

3

1

5

7

4

6

8

A

B

C

D

M

Q1

MAN

BC

2

S1

(ii)

(ii)

(i)

S2

3

1

5

7

4

6

8

A

B

C

D

M

Q1

MAN

BC

2

24

14

Wh

Wh

22

12

Rd

Rd

Bk

Bk

21

11

E

D

N.B.: Gli schemi indicati nelle figure rappresentano l’interruttore aperto con molle del motore cariche.

A

tt

.:  In the figures the C.b. is represented in open position, with spring’s motor loaded.

CARATTERISTICHE / 

teCHNICal CHaraCterIStICS

TEMPO TOTALE AP RIPRISTINO

total oPeNING tIMe + reSet

TEMPO CHIUSURA

CloSING tIMe

POTENZA ASSORBITA 

ALLO SPUNTO

Start INPut PoWer

TENSIONE

VoltaGe

  24V dc
  48V dc
  24V ac

  48V ac
110V ac
230V ac

2 s

2 s

≤ 100 ms

300 Va

≤ 100 ms

300 W

UTILIZZO IN COMMUTAZIONE AUTOMATICA

 Attenzione

:

 in relazione alla modalità di utilizzo del motore con le seguenti combinazioni:

• Senza sganciatore 
  oppure

• Con  sganciatore  (M5T/…. O M4M/….)
Il tempo  di commutazione tra  linea  principale e secondaria (tempo che  intercorre 

fra  l’apertura  dell’interruttore  della  linea  principale  e  la  chiusura  di  quella  della 

secondaria  o  viceversa)  dovrà  essere  impostato  in  modo  da  risultare  maggiore  o 

uguale rispettivamente a:
• 6 secondi

  oppure   

• 0,5 secondi

USE FOR AUTOMATIC CHANGEOVER

 

Caution

: according to the use mode of the motor that is:

• without tripping device

  or

• with tripping device (Bticino M5M/….M4M/….)
The changeover time between main and secondary line (time between the opening 

of the breakers of the main line and the closing of the breakers of the secondary line 

and viceversa) should be setted at a value bigger or equal respectively to:
• 6 sec

   or

• 0,5 sec

Comando mantunuto

Riarmo volontario 

Switch operated 

Volontary reset

Chiusura

Closing

apertura e ricarica

Open and change

MORSETTO

luG

FUNZIONE

FuNCtIoN

1

alimentazione di chiusura /  

Closing power supply

2
3

alimentazione di apertura /  

Opening power supply

4
5

NO (250 

Vac/2a)

Molle cariche /  

Spring loaded

6
7

Non collegati /  

Not connected  

8

Comando impulsivo

Riarmo volontario 

Comando impulsivo

Riarmo automatico dopo lo sgancio 

Push buttom operated 

Volontary reset

Push buttom operated 

automatic reset after trip

Chiusura

Closing

Chiusura

Closing

apertura e ricarica

Open and change

apertura e ricarica

Open and change

Summary of Contents for MA400/630E

Page 1: ...rimossa in questa modalità di funzionamento ATT The cover shield must not be removed in this operation mode FUNZION MANUALE MANUAL OPERATION Chiusura e apertura esclusivamente tramite i pulsanti 3 e 4 Closing and opening only through the push bottons 3 4 Riarmo esclusivamente con leva 1 Reset only through the lever 1 BLOCCO IN APERTO LOCK IN OPEN POSITION Impedisce l esecuzione di manovre Stops an...

Page 2: ... il primo diaframma Take the frame out and cut the small window Applicare la targhetta Stick the label Eliminare il secondo diaframma Cut the second window N B Portare il selettore 5 modalità di funzionamento sulla posizione MAN ATT Set the mode selector 5 on position MAN Montare il coperchietto interruttore Mount the small breaker s cover Montare la base motore sull interruttore Mount the motor o...

Page 3: ...5 Interruttore automatico o di manovra Automatic C B or isolator Contatto protezione coperchio Contacts for cover s protection Relè monostabile 2 N O Tipo art FM4A FM2AC Release 2 N O Pulsante monostabile N O Tipo art F51NA Release N O BC M Comando a motore Motor operator S1 Comando a camma segnale di molle cariche Cam control spring loaded indication Bobina di chiusura Closing coil Pulsante di ch...

Page 4: ...ore oppure Con sganciatore M5T O M4M Il tempo di commutazione tra linea principale e secondaria tempo che intercorre fra l apertura dell interruttore della linea principale e la chiusura di quella della secondaria o viceversa dovrà essere impostato in modo da risultare maggiore o uguale rispettivamente a 6 secondi oppure 0 5 secondi USE FOR AUTOMATIC CHANGEOVER Caution according to the use mode of...