background image

7

346812

15/10/2013

BT00653-a-

PIVOT 4 key 

handset accessory

EN

Configuration

Example 8 - MOD = 7 Intercom in two-family systems

- Key 

1

 Calls the handsets of the same apartment (the handsets configured with the same N as the one the call is made from)

- Key 

2

 Calls the handsets of the other apartment (the handsets configured with a different N from the one the call is made from)

- Key 

3

 Opens the door lock associated with the EP configured with P + 1

- Key 

4

 Opens the door lock associated with the EP configured with P + 2

3

PS

BU S

TK

BU S

PI

230 Vac

1

2

3

4

1

2

3

4

2

2

2

2

346830

N

P

2

N

P

2

N

P

1

BUS 2 1

BUS

MOD=7

P=0

P=1

PE

main

PE

main (P+1)

Power supply 346000

BUS

MOD=7

N

P

1

2

N

P

1

Apartment 2

N

P

2

Apartment 1

2

2

2

PE

audio (P+2)

P=2

4

O

O

O

O

P=2

P=1

P=0

IP30

PRI

PRI 230 V~ 50 - 60 Hz  260 mA

346000

}

BUS

2 - 1

27V      1,2A

CEBEC

N

N F

NOTE:

 Maximum 3 devices per apartment.

Press repeatedly 

 for entrance panel cycling.

It calls the handsets (general call) 
configured with 2 (other devices 
in apartment 2), same apartment 
intercom

It calls the handsets (general 
call) configured with 1 (devices in 
apartment 1), intercom between 
apartments

It calls the handsets (general call) 
configured with 1 (other devices 
in apartment 1), same apartment 
intercom

It calls the handsets (general 
call) configured with 2 (devices in 
apartment 2), intercom between 
apartments

1

2

3

4

1

2

3

4

1

2

3

4

1

2

3

4

NOTE:

 Maximum 3 PIVOT devices per apartment 

with MASTER-SLAVE function.

Summary of Contents for 346812

Page 1: ...mode M Operating mode It sets the operating mode allocated to the individual keys of the accessory block The mode changes depending on whether the apartment interface 346850 has been installed or not...

Page 2: ...onfigured with MOD 5 and P P 3 4 346200 configured with MOD 5 and P P 4 Door lock actuator 346230 346260 1 Actuator configured with P 1 2 Actuator configured with P 2 3 Actuator configured with P 3 4...

Page 3: ...c 230V a c 230V a c 230V a c BUS MOD 0 346200 346200 346200 MOD 9 P 1 MOD 9 P 3 MOD 9 P 4 Main PE Power supply 346000 346200 MOD 9 P 2 230V a c BUS BUS IP30 PRI PRI 230 V 50 60 Hz 260 mA 346000 BUS 2...

Page 4: ...ys call in succession the apartments configured with N 1 N 2 N 3 N 4 Activation of additional door locks Handset with N 1 Call to the Pushbutton 1 1 Handset 2 Pushbutton 2 2 Handset 3 Pushbutton 3 3 H...

Page 5: ...1 door lock of EP P 1 intercom call to N 2 intercom call to N 3 NOTE The operating mode of the intercom function is the same as explained in example 2 In this case however the intercommunication is o...

Page 6: ...local EP door lock of local EP intercom call to N 1 intercom call to N 2 Auto switching on of the local EP door lock of local EP intercom call to N 1 intercom call to N 3 Auto switching on of the loc...

Page 7: ...PE main PE main P 1 Power supply 346000 BUS MOD 7 N P 1 2 N P 1 Apartment 2 N P 2 Apartment 1 2 2 2 PE audio P 2 P 2 4 O O O O P 2 P 1 P 0 IP30 PRI PRI 230 V 50 60 Hz 260 mA 346000 BUS 2 1 27V 1 2A CE...

Page 8: ...key 4 to switch the selected sound source off and activate the audio on the loudspeakers Once the handset has been replaced the sound source comes on again 230 Vac 2 N P 3 MOD 7 P 0 PE main N P 2 2 B...

Page 9: ...9 02 346812 15 10 2013 BT00653 a Assembly Installation PIVOT 4 key handset accessory EN...

Reviews: