background image

5

F420

DE L

A

1

PL

1

2

3

4

MOD=9

Scenario 1/16
Scenario 2/16
Scenario 3/16
Scenario 4/16

346812

15/10/2013

BT00653-a-

Configuration

Example 5 - MOD = 9

Control of the first 4 scenarios (1-2-3-4) of the 16 saved in the F420 scenario module.

PIVOT 4 key 

handset accessory

EN

Scenario modules

Example 6 - MOD = 3 (mixed mode)

Auto-switching on of the EP (P+1)
door lock of sec. EP (P+1)
intercom call to N=1
intercom call to N=2

Auto-switching on of the EP (P+1)
door lock of EP (P+1)
intercom call to N=1
intercom call to N=3

Auto-switching on of the EP (P+1)
door lock of EP (P+1)
intercom call to N=2
intercom call to N=3

NOTE:

 The operating mode of the intercom 

function is the same as explained in example 2. 
In this case however the intercommunication 
is only established among 3 apartment, or 3 
handsets for one-family installations.

- Key 

1

 Auto-switching on of the EP (configured with P+1)

- Key 

2

 Activation of the door lock of the EP (configured with P+1), directly, without call

- Key 

3

 Intercom function

- Key 

4

 Intercom function

230V a.c.

PS

BU S

TK

BU S

PI

1

2

3

4

1

2

3

4

2

2

2

2

2

1

2

3

4

346830

N

P

3

N

P

2

N

P

1

2

1

O

BUS 2 1

BUS

MOD=3

P=0

P=1

PE

PE 

(P+1)

Power supply 346000

BUS

MOD=3

MOD=3

clack

clack

IP30

PRI

PRI 230 V~ 50 - 60 Hz  260 mA

346000

}

BUS

2 - 1

27V      1,2A

CEBEC

N

N F

Summary of Contents for 346812

Page 1: ...mode M Operating mode It sets the operating mode allocated to the individual keys of the accessory block The mode changes depending on whether the apartment interface 346850 has been installed or not...

Page 2: ...onfigured with MOD 5 and P P 3 4 346200 configured with MOD 5 and P P 4 Door lock actuator 346230 346260 1 Actuator configured with P 1 2 Actuator configured with P 2 3 Actuator configured with P 3 4...

Page 3: ...c 230V a c 230V a c 230V a c BUS MOD 0 346200 346200 346200 MOD 9 P 1 MOD 9 P 3 MOD 9 P 4 Main PE Power supply 346000 346200 MOD 9 P 2 230V a c BUS BUS IP30 PRI PRI 230 V 50 60 Hz 260 mA 346000 BUS 2...

Page 4: ...ys call in succession the apartments configured with N 1 N 2 N 3 N 4 Activation of additional door locks Handset with N 1 Call to the Pushbutton 1 1 Handset 2 Pushbutton 2 2 Handset 3 Pushbutton 3 3 H...

Page 5: ...1 door lock of EP P 1 intercom call to N 2 intercom call to N 3 NOTE The operating mode of the intercom function is the same as explained in example 2 In this case however the intercommunication is o...

Page 6: ...local EP door lock of local EP intercom call to N 1 intercom call to N 2 Auto switching on of the local EP door lock of local EP intercom call to N 1 intercom call to N 3 Auto switching on of the loc...

Page 7: ...PE main PE main P 1 Power supply 346000 BUS MOD 7 N P 1 2 N P 1 Apartment 2 N P 2 Apartment 1 2 2 2 PE audio P 2 P 2 4 O O O O P 2 P 1 P 0 IP30 PRI PRI 230 V 50 60 Hz 260 mA 346000 BUS 2 1 27V 1 2A CE...

Page 8: ...key 4 to switch the selected sound source off and activate the audio on the loudspeakers Once the handset has been replaced the sound source comes on again 230 Vac 2 N P 3 MOD 7 P 0 PE main N P 2 2 B...

Page 9: ...9 02 346812 15 10 2013 BT00653 a Assembly Installation PIVOT 4 key handset accessory EN...