![background image](http://html1.mh-extra.com/html/bticino/344662/344662_manual_2825164003.webp)
3
ST-00000472-
344662
EN
17/07/2019
Classe100 V16B Video internal unit
with inductive loop
MODE
KEY
FUNCTION
NOTES
M = 00
Direct EP door lock
activation
(EP configured with the same P), or activation of the EP upon
connection
Activation of the EP
(configured with the same P) directly without call.
Scrolling of EP and cameras installed in the system. Direct call to the switchboard, if present in
the system and appropriately configured.
Actuator
activation
for staircase light pushbutton
M = 01
Direct EP door lock
activation
(EP configured with the same P), or activation of the EP upon
connection
Activation of the EP
(configured with the same P) directly without call.
Scrolling of EP and cameras installed in the system. Direct call to the switchboard, if present in
the system and appropriately configured.
EP door lock release
(configured with P+1), directly without call, or activation of the
actuator 346210 - 346200 (configured with P+1 and MOD=5), or activation of door lock
actuators 346230 - 346260 (configured with P1)
M = 02
Direct EP door lock
activation
(EP configured with the same P), or activation of the EP upon
connection
Internal
intercom
. It sends the call to all the internal units with the same address
Actuator
activation
for staircase light pushbutton
M = 03
Direct EP door lock
activation
(EP configured with the same P), or activation of the EP upon
connection
Activation of the EP
(configured with the same P) directly without call.
Scrolling of EP and cameras installed in the system. Direct call to the switchboard, if present in
the system and appropriately configured.
Internal
intercom
. It sends the call to all the internal units with the same address.
M = 04
Direct EP door lock
activation
(EP configured with the same P), or activation of the EP upon
connection
“PRESET INTERCOM” function with intercommunicating call to the Handset configured with
N=1.
From the system handsets it is possible to send an intercom call to the handset configured with
N= 1.
The internal unit configured with N=1 receives Intercom calls but does NOT send them.
Actuator
activation
for staircase light pushbutton
M = 05
Direct EP door lock
activation
(EP configured with the same P), or activation of the EP upon
connection
Activation of the EP
(configured with the same P) directly without call.
Scrolling of EP and cameras installed in the system. Direct call to the switchboard, if present in
the system and appropriately configured
Intercom
inside the apartment, in systems with apartment interface 346850, or
intercom
among apartments in systems without apartment interface
N=1
N=2
N=2
N=1
M = 06
Direct EP door lock
activation
(EP configured with the same P), or activation of the EP upon
connection
Activation of the EP
(configured with the same P) directly without call.
Scrolling of EP and cameras installed in the system. Direct call to the switchboard, if present in
the system and appropriately configured
General
intercom
, it sends the call to all the apartment devices, in systems with apartment
interface 346850, or
intercom
towards all the apartment devices in systems without
apartment interface 346850
M = 07
Direct EP door lock
activation
(EP configured with the same P), or activation of the EP upon
connection
Activation of the EP
(configured with the same P) directly without call.
Scrolling of EP and cameras installed in the system. Direct call to the switchboard, if present in
the system and appropriately configured
Activation of the EP
(configured with P+1) directly without call or activation of the actuator
346200 – 346210 (configured with P+1 and MOD=9)