background image

1

www.bticino.com

ST-00000691-

344652

B

A

C

A

B

C

164 mm

165 mm

20,5 mm

2

10

9

3

5

4*

7

1

8

6

17/03/2020

EN

Classe100 V16B handsfree video  

internal unit

2 WIRES handsfree video internal unit with 5” colour LCD display.
It has 2 physical keys for the control of the main video door entry functions – answer 
and end a call – and 3 capacitive keys that allow the door lock release, the entrance 
panel activation/scrolling and the customisation of most frequently used quick 
action – e.g. staircase light control, intercom, additional door lock activation, generic 
activations.
The device has a side joystick to adjust: colour, brightness and display contrast, audio 
and call tone volume.
There is a call exclusion notification LED.
The installation can be made to the wall using the bracket (supplied) or using table 
support to be purchased separately.

Power supply 

18 – 27 Vdc

Stand by absorption 

10 mA

Max. absorption 

250 mA max

Maximum cable section for each clamp 

2 x 1 mm

2

Operating temperature 

5 – 40 °C

344692  Tabletop support

Description

Dimensional data

Technical data

Related items

Front view

Legend

When pressed, the keys light up and emit a “beep” (that can be deactivated by procedure).

1. 

Loudspeaker 

2. 

5” (16:9) display 

3. 

Bell exclusion notification LED 
Red LED flashing: bell excluded

4. 

Door lock release touch key *

5. 

Entrance panel/scrolling activation touch key

6. 

Tactile guides for the blinds

7. 

Communication enabling key  
Red LED flashing: call in progress

8. 

Microphone

9. 

Favourites/staircase light control touch key

10. 

Communication enabling key 
Green LED flashing: incoming cal

* If the LEDs flash white when pressed, the “safe door lock” function is active and 

the key is deactivated.

Summary of Contents for 344652

Page 1: ...tion can be made to the wall using the bracket supplied or using table support to be purchased separately Power supply 18 27Vdc Stand by absorption 10 mA Max absorption 250 mA max Maximum cable section for each clamp 2 x 1 mm2 Operating temperature 5 40 C 344692 Tabletop support Description Dimensional data Technical data Related items Front view Legend Whenpressed thekeyslightupandemita beep that...

Page 2: ...e configurators connected to the N sockets of the device assign an identification number within the system to each video internal unit The internal units must be configured in progressiveorder Internalunitswithparallelconnection max3areallowedinsideapartmentswithoutitem346850 mustbeconfiguredusingthesameNconfigurator Inparallelwith the main video internal unit additional internal units video inter...

Page 3: ...ame address M 04 Direct EP door lock activation EP configured with the same P or activation of the EP upon connection PRESET INTERCOM function with intercommunicating call to the Handset configured with N 1 From the system handsets it is possible to send an intercom call to the handset configured with N 1 The internal unit configured with N 1 receives Intercom calls but does NOT send them Actuator...

Page 4: ...tings Settings menu You must use the joystick on the side of the device to navigate on the menu and select the settings SYMBOL ACTIONSTO BE PERFORMED FUNCTION Press Confirm access the Adjustments mode 8 sec Press and hold down for more than 8 sec Access the Settings mode Move the joystick up when released it returns to central position Previous page increase level Move the joystick down when relea...

Page 5: ...3 2020 EN Classe100 V16B handsfree video internal unit Adjustments ADJUSTMENTS MENU From stand by press the joystick to activate the display Adjust the ringtone volume Exit the menu Move the joystick up down to select the page among ...

Page 6: ...ding page 1 Press the joystick to adjust the volume The ringtone is played at the set volume level 2 Move the joystick up down to select the volume level 1 8 4 Move the joystick up down to select another setting or the last page to exit 3 Press the joystick to confirm the setting or wait for the timeout The minimum level corresponds to the exclusion of the ringtone The corresponding LED flashes re...

Page 7: ...y the parameters The page shows the type of parameter A and the set level B 2 Move the joystick up down to select the type of parameter for which you want to modify the value see the following table ICON TYPE OF PARAMETER Speaker volume Parameter that can be adjusted only with active audio Image brightness Image contrast Image colour 4 Move the joystick up down to select the desired level 6 Move t...

Page 8: ...nal unit From stand by press and hold down the joystick for about 8 seconds to activate the display and access the Settings menu Enable disable the key sound Associate a ringtone to an event Exit the menu Move the joystick up down to select the page among 8 sec Settings SETTINGS MENU ...

Page 9: ...o modify the ringtones associated to the different types of call The ringtones played for calls from EP configured with S 2 and S 3 are set by default and cannot be changed From stand by press and hold down the joystick for about 8 seconds to access the advanced menu and select the corresponding page ICON TYPE OF CALL 0 Selection of the call ringtone from the MAIN ENTRANCE PANEL S 0 1 Selection of...

Page 10: ...e associated the ringtone is played 6 Move the joystick up down to select another call or the last page to exit 3 Press the joystick to continue 5 Press the joystick to confirm or wait for the timeout When active this function prevents the opening of the entrance panel door lock when the internal unit is in stand by Therefore the opening of the door lock is only permitted when entrance panel and i...

Reviews: