background image

5

344082

BT00641-a

-EN

TECHNICAL SHEETS

MODE

KEY

FUNCTION

NOTES

6

MOD = 

1

Activation of the scenario saved in the scenario module

(SCENARIO 1)

2

Activation of the scenario saved in the scenario module

(SCENARIO 2)

3

EP door lock release 

(configured with P+1), directly, without call, or activation of 

the actuator, item 346200 (configured with P+1 and MOD=5), or activation of door 
lock actuators 346230-346260 (configured with P+1)

4

EP door lock release 

(configured with P+2), directly, without call, or activation of 

the actuator, item 346200 (configured with P+2 and MOD=5), or activation of door 
lock actuators 346230-346260 (configured with P+2)

7

MOD = 

1

Intercom

 inside the apartment, in systems with apartment interface item 346850, 

or 

intercom

 among apartments without apartment interface.

1

N=1

N=3

1

N=2

N=1

1

N=3

N=1

2

Intercom

 inside the apartment, in systems with apartment interface item 346850, 

or 

intercom

 among apartments without apartment interface.

2

N=1

N=2

2

N=2

N=3

2

N=3

N=2

3

Activation of the scenario saved in the scenario module

(SCENARIO 1)

4

Activation of the scenario saved in the scenario module

(SCENARIO 2)

8

MOD = 

1

Activation of the scenario saved in the scenario module

(SCENARIO 1)

2

Activation of the scenario saved in the scenario module

(SCENARIO 2)

3

Activation of the scenario saved in the scenario module

(SCENARIO 3)

4

Activation of the scenario saved in the scenario module

(SCENARIO 4)

1

MOD = 

1

General 

Intercom, sends a call to all the handsets of the system.

2

EP activation 

(configured with P+1), directly, without call, or activation of the 

actuator, item 346200 (configured with P+1 and MOD=9)

3

EP door lock release

 (configured with P+1), directly, without call, or activation of 

the actuator, item 346200 (configured with P+1 and MOD=5), or activation of door 
lock actuators 346230-346260 (configured with P+1)

4

EP door lock release 

(configured with P+2), directly, without call, or activation of 

the actuator, item 346200 (configured with P+2 and MOD=5), or activation of door 
lock actuators 346230-346260 (configured with P+2)

1 2

MOD = 

1

Intercom

 between apartments, in systems with apartment interface, item 346850

1

N=1

2

Intercom

 between apartments, in systems with apartment interface, item 346850

2

N=2

3

EP door lock release 

(configured with P+1), directly, without call, or activation of 

the actuator, item 346200 (configured with P+1 and MOD=5), or activation of door 
lock actuators 346230-346260 (configured with P+1)

4

EP door lock release 

(configured with P+2), directly, without call, or activation of 

the actuator, item 346200 (configured with P+2 and MOD=5), or activation of door 
lock actuators 346230-346260 (configured with P+2)

Summary of Contents for 344082

Page 1: ...isabledpeople Fixing bracket supplied Technical data Power supply from SCS BUS 18 27Vdc Stand by absorption 5 mA Max operating absorption 55 mA Operating temperature 5 40 C Legend 1 Call signalling LED 2 Loudspeaker 3 Staircase light key 4 Loudspeaker volume adjustment 5 Connection key LED 6 Microphone 7 Door lock key LED 8 Bell volume adjustment and exclusion LED 9 EP Activation cycling 10 4 prog...

Page 2: ...tion to the door lock opening key and the staircase light key the handset also has 4 programmable keys These keys may be associated to different operating modes e g activation of external actuators intercom activation of additional EPs etc based on the type of configurator connected to M Thehandsetoffersthepossibilitytoselectamong16typesofbellswithpre programmed ringtones which can be associated t...

Page 3: ...ts without apartment interface 2 N 1 N 2 2 N 2 N 3 2 N 3 N 2 3 EP activation configured with P 1 directly without call or activation of the actuator item 346200 configured with P 1 and MOD 9 4 EP door lock release configured with P 1 directly without call or activation of the actuator item 346200 configured with P 1 and MOD 5 or activation of door lock actuators 346230 346260 configured with P 1 2...

Page 4: ...nterface 2 N 1 N 2 2 N 2 N 1 3 EP door lock release configured with P 1 directly without call or activation of the actuator item 346200 configured with P 1 and MOD 5 or activation of door lock actuators 346230 346260 configured with P 1 4 EP door lock release configured with P 2 directly without call or activation of the actuator item 346200 configured with P 2 and MOD 5 or activation of door lock...

Page 5: ... scenario saved in the scenario module SCENARIO 2 3 Activation of the scenario saved in the scenario module SCENARIO 3 4 Activation of the scenario saved in the scenario module SCENARIO 4 1 MOD 1 General Intercom sends a call to all the handsets of the system 2 EP activation configured with P 1 directly without call or activation of the actuator item 346200 configured with P 1 and MOD 9 3 EP door ...

Page 6: ...6850 3 N 3 4 Intercom between apartments in systems with apartment interface item 346850 4 N 4 1 6 MOD 1 Activation of the scenario saved in the scenario module SCENARIO 1 2 Activation of the scenario saved in the scenario module SCENARIO 2 3 General Intercom sends a call to all the handsets of the system 4 EP door lock release configured with P 1 directly without call or activation of the actuato...

Page 7: ...7 27 47 67 87 0 8 28 48 68 88 A Configuration selected for the operation of the keys see previous pages B Configuration selected for the operation of the keys OFFICE function C Configuration selected for the operation of the keys PAGING function D Configuration selected for the operation of the keys HANDSFREE function Can be activated only on a single device for each unit system E Configuration se...

Page 8: ...N TECHNICAL SHEETS OFFICE FUNCTION DETAIL With the function active when a call is received from the entrance panel the video handset rings and the associated door lock is automatically released without the need for pressing the door lock release key on the handset To ENABLE the function To DISABLE the function WARNING the OFFICE function cannot be activated together with the DOOR STATUS function ...

Page 9: ...ty of communication To enable the PUSHTOTALK function during the conversation proceed as follows PresstheConnectionkeyforatleast2seconds toenablethecommunicationwiththe entrance panel The LED stays green Release the key to listen to the entrance panel The LED turns red To end the connection press the Connection key briefly The LED turns off This function can be used to send voice messages using th...

Page 10: ...T OK 1 17 2 3s 4 4 4 EXIT OK 1 17 2 3s EXIT OK 1 17 2 3s 2 2 2 EXIT OK 1 16 2 3s 1 1 1 EXIT OK 1 17 2 3s 3 3 3 EXIT OK 1 17 2 3s 4 4 4 EXIT OK 1 17 2 3s EXIT OK 1 17 2 3s 2 2 2 EXIT OK 1 17 2 3s 1 1 1 EXIT OK 1 17 2 3s 3 3 3 EXIT OK 1 17 2 3s 4 4 4 EXIT OK 1 16 2 3s EXIT OK 1 17 2 3s 2 2 2 EXIT OK 1 17 2 3s 1 1 1 EXIT OK 1 17 2 3s 3 3 3 EXIT OK 1 16 2 3s 4 4 4 EXIT OK 1 17 2 3s EXIT OK 1 17 2 3s 2...

Reviews: