BTCPower 200 KW EVSE Installation manual 

Rev K 

Page  21 of 26

 

 

 

8.

 

Installation Line Drawing 200 KW Configuration

 

 

 

 

Note: Conduit #2 shall contain optical, shielded interlock wire and CAT6 wire.  

 

Note: Interlock between dispenser and tower will shut down DC output from tower to dispenser 

when charge post not enabled or when power to the tower is removed.  In addition, contactors on 

both the tower as well as dispenser assure no voltage can be present on the dispenser input when 

the tower is disabled.  

 

 

 

 

 

 

 

Summary of Contents for EVSE 200 KW

Page 1: ...r opening 7 Conduit windows 8 Changed dispenser auxiliary to 120 VAC single phase Cortes C 1 29 2017 1003 1 Added three dispenser 50 KW configuration Cortes D 1 30 2018 1004 1 Added 50 KW auxiliary po...

Page 2: ...r sale or manufacture of apparatus without written permission BTCPower 200 KW EVSE Installation manual Rev K Page 2 of 26 200 KW EVSE CHARGER 2 Cold weather heater integrated Auxiliary power added for...

Page 3: ...allation Line Drawing 200 KW Configuration 21 9 Installation Line Drawing 50 KW Configuration 22 10 Dispenser Template 23 11 Power Conversion Tower Template 24 12 Maintenance 25 a Maintenance Precauti...

Page 4: ...ation guidelines IMPORTANT SAFETY INSTRUCTIONS The following symbols may be found in your handbook or on labels affixed to your conductive charge station DANGER Danger indicates a hazard or unsafe pra...

Page 5: ...tandards for Accessible Design http www ada gov 2010ADAstandards_index htm The Department of Justice published revised regulations for Titles II and III of the Americans with Disabilities Act of 1990...

Page 6: ...ons please visit the Department s website www ADA gov or for answers to specific questions call the toll free ADA Information Line at 800 514 0301 Voice or 800 514 0383 TTY 2 2 Equipment Description W...

Page 7: ...power module 2 7 Output Contactors power module 3 8 Output Contactors power module 4 9 Air Cooling Vent 10 Master Controller 11 Safety Relays 12 24vdc Power Supply 13 5 12 15 15 vdc Power Supply 200...

Page 8: ...Box Quad output SCCR 65 KA EVPC 200 4 480 3 65 PC200465 7 DCFC Dispenser CCS CHAdeMO EVDSP 350 5 120 0 2 C 4 0 DSP3505CHACCS 8 DCFC Dispenser Dual CCS EVDSP 350 3 120 0 2 C 4 0 DSP35032XCCS 9 DCFC Dis...

Page 9: ...liary power 120 VAC Single phase 20 Amps Both CHAdeMO CCS and CCS CCS models Connectors available CCS only HPC CCS Huber Suhner Connectors available CHAdeMO only SEI Sumitomo Electric 200 Amp Continuo...

Page 10: ...eter Specification Specification Input Voltage Range 480 VAC three phases 10 10 480 VAC three phases 10 10 Input Current 480 VAC 240 Amps 240 Amps Frequency 47 63 Hz for three phase inputs 47 63 Hz fo...

Page 11: ...Power 50 KW per output 4 simultaneous up to 200 KW Max Output Current 125 Amps per output Minimum Current In current mode 5 Amps Enclosure IK rating IK 08 Enclosure IP rating IP 54 Total Harmonic Dist...

Page 12: ...r UL 2231 EMC requirements 6 KV requirement per UL 2231 EMC requirements External Remote E Stop Remove high power if external E stop is activated Remove high power if external E stop is activated GROU...

Page 13: ...ssion BTCPower 200 KW EVSE Installation manual Rev K Page 13 of 26 Fig 1 AC input terminal lugs DC Converter Output terminal block from converter to dispenser single and dual high output configuration...

Page 14: ...WIRE RANGE OPENINGS PER POLE PART NUMBER AMPERE RATING Terminal Block Mersen Cu wire 2 0 14 1 MPDB63153 175 Torque requirement per UL E file Mersen MPDB63153 Terminal block primary side from converte...

Page 15: ...tinuous 250 Amps Maximum DC Output Current CHAdeMO continuous 200 Amps Minimum Current In current mode 5 Amps DC power input voltage range 50 920 VDC DC power input current range 5 Amps 500 Amps Outdo...

Page 16: ...ge range 50 920 VDC DC power input current range 5 Amps 500 Amps Outdoor enclosure NEMA 4 IP 54 equivalent Chilled 50 50 ethylene glycol 20 C input Temperature Flow rate 10 l min Weight 600 lbs LED li...

Page 17: ...eproduced or used as the basis for sale or manufacture of apparatus without written permission BTCPower 200 KW EVSE Installation manual Rev K Page 17 of 26 Auxiliary 120 VAC Single Phase 20 Amps Optic...

Page 18: ...or additional details Cable Length o 4 5 meter outside length standard o Optional longer length available Cable Management System o None This will be a non retractable cable system 5 Electrical and co...

Page 19: ...steel pedestal provided with the BTCP EV Charging Station WARNING BTCP EV Charging Station can only be installed onto undamaged concrete slab A minimum of 4 expansion bolts should be mounted on the bo...

Page 20: ...ear the fault 230 Over current This is a hard fault that results in out of service Press STOP and then START to restart the application to clear the fault 240 Over temperature This is a hard fault tha...

Page 21: ...of 26 8 Installation Line Drawing 200 KW Configuration Note Conduit 2 shall contain optical shielded interlock wire and CAT6 wire Note Interlock between dispenser and tower will shut down DC output f...

Page 22: ...d reproduced or used as the basis for sale or manufacture of apparatus without written permission BTCPower 200 KW EVSE Installation manual Rev K Page 22 of 26 9 Installation Line Drawing 50 KW Configu...

Page 23: ...f Broadband Telecom Power Inc and will not be copied reproduced or used as the basis for sale or manufacture of apparatus without written permission BTCPower 200 KW EVSE Installation manual Rev K Page...

Page 24: ...band Telecom Power Inc and will not be copied reproduced or used as the basis for sale or manufacture of apparatus without written permission BTCPower 200 KW EVSE Installation manual Rev K Page 24 of...

Reviews: