Functions and parameters
Operating principle
© BT
Repair manual
SWE100, 120, 120L, 120S, 140, 140L, 200D
6 – 7
Order no..
Date
Valid from serial no.
T code
258946-120
2012-08-30
6061850-
841×842×843
Influencing
elements
Main contactor [Q10].
Button for support arm lowering [A5:S22].
Resulting
conditions
[T1:OUT. LOWER VALVE] goes {low}, proportional valve [Q4] opens.
Event:
14.
Click-2-Creep
Preceding
event(s)
Start the truck.
Action(s)
Rapid double-actuation of the speed control to activate the function.
Set the tiller arm in the vertical position and drive the truck at creep speed
(2.5 km/h).
Influencing
elements
Main contactor [Q10].
Setting of factory parameter 1002.
Resulting
conditions
[T1:OUT.BRAKE RELEASE] goes {low}.
Brake coil [Q1] is activated, and the mechanical brake is released.
The pulsed current fed to the drive motor is proportional to speed control
actuation. “SLO” is shown on the display (blinking).
Event:
15. Turtle function (option)
Preceding
event(s)
Lower the tiller arm to the drive position.
Action(s)
Press [S206] to activate this function.
Turn the speed control in either direction.
Influencing
elements
Option button 1 [S206].
Setting of operator parameter 7 and service parameter 202.
Resulting
conditions
[T1: OUT. BRAKE RELEASE] goes {low}.
Brake coil [Q1] is activated, and the mechanical brake is released.
The pulsed current fed to the drive motor is proportional to speed control
actuation. The maximum travel speed is determined by operator
parameter 7. “SLO” is displayed (lights continuously).
https://www.besttruckmanuals.com/