background image

 

1. Cautions 

 

 

This manual describes how to use BT-CSIV Properly. 
Read it carefully to avoid damaging the product and injuring yourself. 
Pay attention to the following series of warnings. 

 

  Use only components provided or approved by BT Inc. 

 

  Do not disassemble, repair, or modify this product on your own. 

 

  Keep the product away from water. If the product gets wet, do not turn it on. You could be 
injured by electric shock. 

 

  Do not use the product near strong magnetic fields or high voltage power lines. The product 

might malfunction due to electromagnetic waves. 
 

  Do not use the product under a condition of thunder and lightning. It can cause the product 

malfunction and increases the risk of electric shock. 
 

  Do not use the product in locations with temperatures below 0

  or above 40

(Operation temperature : 0

  ~ 40

, Storage temperature : -10

  ~ 50

 

  Do  not  keep  the  product  near  hot  places  such  as  heaters.  Transformation  of  product  or 

internal damage might occur. 

 

  Never  clean  the  product  with  chemical  substances  such  as  solvent,  benzene  or  thinner,  as 

these may cause ignition, electric shock or cause the surface to deteriorate. 

 

  BT Inc. can change or adjust the product specification without any notice in order to improve 

the product.   
 

Summary of Contents for bt-csiv2

Page 1: ...USER GUIDE Arm Manikin for IV Access Training BT CSIV2 ...

Page 2: ...t might malfunction due to electromagnetic waves Do not use the product under a condition of thunder and lightning It can cause the product malfunction and increases the risk of electric shock Do not use the product in locations with temperatures below 0 or above 40 Operation temperature 0 40 Storage temperature 10 50 Do not keep the product near hot places such as heaters Transformation of produc...

Page 3: ...2 2 Table of Contents 1 Cautions 1 2 Table of Contents 2 3 Components 3 4 Features and Functions 4 5 Installation 6 6 User Manual 8 7 Cleaning and Storage 10 ...

Page 4: ... manikin mount Volumetric pump installed 1ea Microcomputer installed 1ea Volume pump Control 1ea Timer Switch 1ea One touch fitting for connection tube 2ea 3 Accessories Mount 1ea Simulated blood 30ml 1ea Plastic bottle 1ea Power source adapter 9VDC 1ea Battery Holder 1ea Connection tube 3ea Storage case 1ea ...

Page 5: ...ctions Arm manikin Skin pad Vein tube installed Blood circulation controller Installed in Arm Manikin Manikin Mount Timer switch Rapid blood circulation switch Blood IN connector Blood OUT connector Power supply connector ...

Page 6: ...5 Plastic bottle Plastic bottle IN connector Plastic bottle OUT connector Connection tube Mount ...

Page 7: ...power supply Drop a few drops of simulated blood in a plastic bottle with some water and shake it 2 Installation of Skin Pad Take the separate paper on the back of the Skin Pad off Insert the Skin Pad into the gap of the back side of the hand Insert the Skin Pad into the gap all the way to the end of Arm manikin ...

Page 8: ...7 3 Connect the silicon tube as shown below ...

Page 9: ...ear one buzzer sound in about two second Then the LED lamp turns on and blood flows for 5 minutes 6 When you press the Timer Switch more than once you can hear buzzer sounds as shown in the chart below Then blood will flow for several minutes as shown below 7 When you press the Timer Switch 7 times you can hear three buzzer sounds Then blood circulation will stop No of counts for pressing timer sw...

Page 10: ...l stop automatically 9 After termination of the operation you can hear the three buzzer sounds beep beep beep 10 If you want to restart just press the Timer Switch again 11 After finishing the practice please keep the product as described in Chapter 7 Cleaning and Storage ...

Page 11: ...tainer 3 Reconnect the white connector to the Plastic bottle 4 Press the Rapid Blood Circulation Switch in order to circulate the clean water to clean up the tube 5 Disconnect the white connector from the Plastic Bottle and then press the Rapid Blood Circulation Switch to remove clean water in the tube just as 1 6 After pouring the water out of the bottle disconnect the connection tubes 7 If water...

Reviews: