Use only BSX authorized parts and accessories. Parts and accessories not approved for use with 

the device may damage the unit. 

Use only the factory specified battery with this device. 

Do not use other types of battery. This may damage the unit. 

Measurements outside the cuff range are inaccurate and cannot be made, and may cause the cuff 

to fall off during inflation or other unpredictable events. 

The 

Monitor must be recharged every 6 months, otherwise the Limited warranty and the shelf life 

will 

end. 

When the monitor exceeds its service life, sensor and electrode degradation can lead to inaccurate 

measurement accuracy, or electrode looseness can lead to poor contact or other problems. 

 

RISK OF ELECTRICAL SHOCK 

Do not install or remove battery with wet hands. 

CARE AND MAINTENANCE 

Do not subject the monitor to strong shocks, such as dropping the 

unit

 on the floor.   

Do not submerge the device or any of the components in water.   

Store the 

unit

 and the components in a clean, safe location. 

Changes  or  modification  not  approved  by  BSX  will  void  the  user  warranty.  Do  not  disassemble  or 

attempt to repair the 

unit

 or components. 

Changes  or  modification  not  approved  by  the  manufacturer  will  void  the  user  warranty.  Do  not 

disassemble or attempt to repair the 

unit

 or components. No modification of this equipment is allowed. 

If  this  equipment  is  modified,  appropriate  inspection  and  testing  must  be  conducted  to  ensure 

continued safe use of the equipment. 

6  BEFORE TAKING A MEASUREMENT 

To ensure a reliable reading follow these recommendations: 

1)  Avoid  eating,  drinking  alcohol,  smoking,  exercising,  and  bathing  for  30  min  prior  to  taking  a 

measurement. Rest for at least 15 min prior to taking the measurement. 

2)  Stress raises blood pressure, avoid taking measurements during stressful times. 

3)  Measurements should be taken in a quiet place. 

4)  Remove tight-fitting clothing from your Arm. 

5)  Sit on a chair with your feet flat on the floor. Rest your Arm on a table so that the CUFF is at the same 

level as your heart. 

6)  Remain still and do not talk during the measurement. 

7)  Wait 2 to 3 minutes between measurements, the wait time allows the arteries to return to the condition 

prior to taking the blood pressure measurement. You may need to increase the wait time depending on 

Summary of Contents for BSX579B

Page 1: ...ng No 13 Ailian Industrial park Wulian Longgang Shenzhen China Web site http www szbsx com cn Tel 86 755 28719103 Please thoroughly read the Instruction for Use before using the unit Please save this...

Page 2: ...ALLATION AND USE 9 8 1 Battery level Introduction 9 8 2 Using the device used to provide power 9 8 3 Blood Pressure Measurement Method 10 8 3 1 Applying the CUFF 10 8 4 Body Posture During Measurement...

Page 3: ...movements into a digital reading No stethoscope easy to use please read and follow all instructions and warnings before using this product Save these instructions for future reference In this Instruc...

Page 4: ...sent because of temporary interference to blood flow and could result in injury to the PATIENT Avoid the application of the CUFF and its pressurization on the Arm on the side of a mastectomy or lymph...

Page 5: ...overinflated for a long time and the pressure is too high the subject may feel uncomfortable If the feeling is strong please press the START STOP button to relieve pressure or pull out the trachea plu...

Page 6: ...X will void the user warranty Do not disassemble or attempt to repair the unit or components Changes or modification not approved by the manufacturer will void the user warranty Do not disassemble or...

Page 7: ...7 your individual physiological characteristics 8 Cleaning and disinfection of the unit following use to prevent PATIENT cross infection...

Page 8: ...vice for people who cannot express their thoughts correctly including infants and newborns 7 2 Statement 1 The Monitor products manufactured by our company have passed clinical verification and their...

Page 9: ...prepare battery timely 3 When the battery is exhausted Display the exhausted icon It flashes 5 times and monitor will shut off immediately 9 2 Using the device used to provide power 1 To connect the...

Page 10: ...to provide power must meet the requirements of IEC 60601 1 The output of the device used to provide power should be 5V d c 1A connect port USB power port for power supply only no data communication f...

Page 11: ...he CUFF in clothes dryer or iron it Clean the CUFF after the usage of every 200 times is recommended Do not place the CUFF around your Arm if the Arm has any inflammation acute diseases infections ski...

Page 12: ...riumofthe heart ArecommendationthatthePATIENTrelaxasmuchaspossibleandnottalkduringthe measurementPROCEDURE Arecommendation that5minshouldelapse beforethe first readingistaken Measuring on same Arm eac...

Page 13: ...e ERROR AND FAULT INSTRUCTIONS for troubleshooting 2 Stop automatically after full inflation and start to detect the pulse rate In the measuring process End of the measurement Note This pictures in th...

Page 14: ...oon press MEM key to set the hour value 7 Then press the on Off or START STOP key the minute number flashes and enter the setting minute state Press MEM key to set the value of minutes 8 Then press th...

Page 15: ...oval of all measurement data under all users 10 6Entering static pressure measurement method 1 Short press the MEM button then press and hold down the MEM button the START STOP button for about 2s Low...

Page 16: ...PRESSURE MEASUREMENT METHOD Inflate the CUFF 40mmHg higher than the previous inflation value The CUFF is too loose Apply the CUFF correctly Refer to the clause Applying the CUFF Clothing is interferin...

Page 17: ...d pressure Please conduct measurement after the blood flow is smooth 3 When the LCD display an Error code Err the measurement cannot be conducted correctly please refer to the error and fault instruct...

Page 18: ...m entering the pipe The entry of debris into pipe may affect the measurement results or affect the measurement function such as blocking the pipe 13 MAINTENANCE REPAIR AND CALIBRATION 1 When it is not...

Page 19: ...batteries i The manufacturer will make available on request circuit diagrams component part lists descriptions j The patient can perform changing batteries 5 Calibration instructions or other informa...

Page 20: ...l pollution The marking in this manual that the batteries in this product should be disposed with household trash at the end of its working life If the batteries are not disposed of properly the subst...

Page 21: ...order to protect against HAZARDS of ignition of flammable anaesthetic mixtures Distribution packages shall not be exposed to sunlight Contents of the distribution packages are fragile therefore it sh...

Page 22: ...ing First Digit 2 Protected against access to hazardous parts with a finger Second Digit 2 Degrees of protection against water indicated by the second characteristic numeral Non protected 17 PRODUCT S...

Page 23: ...ion environment 20 to 55 10 to 93 RH 70kPa to 106kPa Voice function Support voice broadcast Automatic shutdown Automatic shutdown after about 60 seconds without operation Pressurization way Intelligen...

Page 24: ...obtain warranty service contact Customer Service by calling for the address of the repair location and the return shipping and handling fee Enclose the Proof of Purchase Include a letter with your nam...

Page 25: ...d and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If thi...

Reviews: